The technical progress in the medical sector in the past decades has continuously driven the development of electrosurgical techniques. The controversies surrounding the superiority of a certain technique relative to another - electrocautery, laser and radiofrequency - have determined us to carry out a histopathological design with the aim of comparing the healing sort of the shallow wounds generated by the three types of electrosurgical devices. The experimental study has investigated the healing process inflicted by the electrosurgical devices mentioned beforehand on 12 Wistar albino rats. The wounds were inflicted under intravenous general anesthesia with Xylazine and Ketamine and were performed lateral to the spine region, using laser, radiofrequency and electric cautery. The histological samples harvested at one, three, five, and seven days were sent to pathological examination. We followed by comparison the evolution of the first two phases of the wound healing produced by the three electrosurgical methods analyzed. We described the histopathological changes occurred in the epidermis, dermis and hypodermis and also the subcutaneous soft tissues in all of the three types of lesions. Electrocautery remains the most frequently used electrosurgical device, even if it has unquestionable disadvantages as compared to other modern instruments. Laser-assisted surgery and radiofrequency are refine energy-based instrumentation, being utilized at a multidisciplinary surgical level.
机译:在过去的几十年中,医疗领域的技术进步不断推动着电外科技术的发展。围绕某种技术相对于另一种技术(电灼,激光和射频)的优越性的争论已决定我们进行组织病理学设计,旨在比较由三种类型的电外科设备产生的浅层伤口的愈合类型。实验研究调查了预先提到的电外科设备对12只Wistar白化病大鼠造成的愈合过程。伤口在静脉内全身麻醉下使用甲苯噻嗪和氯胺酮进行损伤,并使用激光,射频和电灼术在脊柱区域外侧进行手术。在第1、3、5和7天收集的组织学样本送至病理检查。我们随后比较了通过分析的三种电外科方法产生的伤口愈合的前两个阶段的演变。我们描述了在这三种类型的病变中,表皮,真皮和皮下组织以及皮下软组织中发生的组织病理学变化。电烙术仍然是最常用的电外科设备,即使与其他现代器械相比,电烙术具有无疑的缺点。激光辅助手术和射频是基于能量的精密仪器,在多学科手术水平上得到了利用。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号