首页> 外文期刊>Open Journal of Medical Imaging >Application of Dual-Energy CT Non-Linear Fusion Technology in Improving CTA Image Quality of Renal Cancer
【24h】

Application of Dual-Energy CT Non-Linear Fusion Technology in Improving CTA Image Quality of Renal Cancer

机译:双能CT非线性融合技术在提高肾癌CTA图像质量中的应用

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objective: To explore the significance of dual-energy CT non-linear fusion technique in improving the quality of CTA image of renal cancer. Methods: The CTA images of 100 patients who had been confirmed by pathology as renal cancer were collected and were randomly divided into experimental group and control group with 50 cases respectively. The two groups of patients were treated with iodine concentration of 300 mg/ml and 350 mg/ml non-ionic contrast agent, with a dosage of 1.5 ml/kg and an injection rate of 4 ml/s. The contrast agent intelligently tracking method was adopted bolus. The control group used the conventional CTA scanning, with a reference tube voltage/tube current of 100 kv/ref150 mas. The experimental group adopted the double energy scanning, with ball tube A and ball tube B. The reference tube voltage/tube current was 100 kv/ref250 mas and sn150 kv/ref125 mas respectively. The images of the experimental group were non-linear fused to obtain the Mono+ 55 kev single-energy images. The CT value, SNR contrast ratio of the abdominal aorta, renal artery and tumor tissue of the experimental group images and the 100 KV images and the Mono+ 55 kev images of the control group were compared. The objective evaluation and subjective evaluation of the image quality of the three groups of images was performed. Results: The results showed that the 100 kV images of the experimental group were statistically different from those of the control group (P05) in CT value, SNR and CNR (P < 0.05). And there was no statistically significant difference between the non-linear fusion single-energy Mono+ 55 kev images and the control group images in CT value, SNR and CNR (P > 0.05). The subjective evaluation of image quality showed that there was no significant difference between Mono+ 55 kev images and control group images, and the quality of Mono+ 55 kev images was higher than that of experimental group 100 kV images. Conclusion: The dual-energy CT non-linear fusion technique can improve the quality of CTA image in patients with renal cancer, and it is possible to obtain high quality CTA images with low iodine concentration contrast agent.
机译:目的:探讨双能CT非线性融合技术对提高肾癌CTA图像质量的重要性。 方法:收集经病理证实为肾癌的100例患者的CTA图像,将其随机分为实验组和对照组,分别为50例。两组患者分别接受碘浓度为300 mg / ml和非离子型造影剂350 mg / ml的治疗,剂量为1.5 ml / kg,注射速度为4 ml / s。造影剂采用智能跟踪方法。对照组使用常规CTA扫描,参考管电压/管电流为100 kv / ref150 mas。实验组采用双能量扫描,球管A和球管B。参考管电压/管电流分别为100 kv / ref250 mas和sn150 kv / ref125 mas。实验组图像进行非线性融合以获得Mono + 55 kev单能图像。比较实验组图像与对照组的100 KV图像和Mono + 55 kev图像的CT值,腹主动脉,肾动脉和肿瘤组织的SNR对比度。对三组图像的图像质量进行客观评估和主观评估。 结果:结果表明,实验组的100 kV图像的CT值,SNR和CNR与对照组(P05)的统计学差异有统计学意义(P <0.05)。非线性融合单能Mono + 55 kev图像与对照组图像的CT值,SNR和CNR差异无统计学意义(P> 0.05)。图像质量的主观评价表明,Mono + 55 kev图像与对照组图像之间无显着差异,Mono + 55 kev图像的质量高于实验组100 kV图像。 结论:双能CT非线性融合技术可以改善肾癌患者CTA图像的质量,并且可以使用低碘浓度造影剂获得高质量的CTA图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号