This paper presents a theoretical and an experimental study on the determination of thermal phase shift time and damping factors of building walls. The work consisted in evaluating the thermal comfort in a building. This study is a contribution to put in place a thermal regulation in Burkina Faso, a country with a dry tropical climate. This regulation will, in its application, reduce the energy consumption related to air conditioning in buildings. To do this, we theoretically determine the parameters influencing this comfort using the admittance method. This method makes it possible to analyze the thermal response of a building to a periodic energy demand. It is based on the modeling of the building component by the quadrupole method resulting from the writing of the thermal problem in the form of transfer matrix products. The principle is to link the flows and temperatures of both sides of a homogeneous wall through the equation of heat and the Fourier transform. The calculation method is validated by experimental results. For simple sheet walls based on their compositions, damping factors range from about 37.9% to 79.7% and thermal phase shift time from about 3.9 hours to 7.4 hours. However, the values of these parameters are better when the walls are double-sheeted, the maximum value of the damping factor is 11.5% and the minimum value of the thermal phase shift time is 9.7 h. The values of Mean Bias Difference (MBD) and Root Mean Square Difference (RMSD) show that the theoretical and experimental results are quite concordant. The admittance method can be used to evaluate the performance of building walls.
机译:本文提出了确定建筑物墙体热相移时间和阻尼因子的理论和实验研究。这项工作包括评估建筑物的热舒适性。这项研究有助于在热带气候干燥的国家布基纳法索实施热量调节。该法规将在其应用中减少与建筑物空调相关的能源消耗。为此,我们在理论上使用导纳法确定影响舒适度的参数。这种方法可以分析建筑物对周期性能量需求的热响应。它基于通过以传递矩阵乘积形式编写热问题而产生的四极杆方法对建筑构件进行建模。原理是通过热量方程和傅立叶变换将均质壁的两侧的流动和温度联系起来。实验结果验证了该计算方法的有效性。对于基于其组成的简单板壁,阻尼系数在约37.9%至79.7%的范围内,热相移时间在约3.9小时至7.4小时的范围内。但是,当将壁板双层放置时,这些参数的值会更好,阻尼系数的最大值为11.5%,热相移时间的最小值为9.7 h。均方差(MBD)和均方根差(RMSD)的值表明,理论和实验结果相当一致。导纳方法可用于评估建筑物墙体的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号