Successful removal of an intractable mucoid impaction in the bronchus using a Fogarty catheter with flexible bronchoscopy

机译:使用带柔性支气管镜的Fogarty导管成功去除支气管中顽固性粘液样撞击

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Rigid bronchoscopy is commonly used as the standard method to diagnosis and remove obstructive material from the tracheobronchial tree. However, a rigid bronchoscope has limitations when removing a foreign body with surface properties that make it difficult to grasp. We experienced a case that involved the removal of a mucoid impaction, which was accompanied by a near-total unilateral lung collapse, using a Fogarty catheter with flexible bronchoscopy.
机译:硬支气管镜检查通常用作诊断和从气管支气管树中清除阻塞性物质的标准方法。但是,硬性支气管镜在去除具有难以抓握的表面特性的异物时具有局限性。我们经历了一个案例,该案例涉及使用带柔性支气管镜的Fogarty导管去除粘液样撞击,并伴有近乎完全的单侧肺塌陷。