Development of a Compact and Sensitive Electrostatic Radon-222 Measuring System for Use in Atmospheric Observation

机译:紧凑,灵敏的Radon-222静电测量系统的开发,用于大气观测

获取原文
           

摘要

A new automated 222Rn measuring system suitable for a wide range of atmospheric observations has been developed. This system comprises a 222Rn analyzer and an air-sampling unit, along with a pump, drying equipment, and a filter. The operation of this 222Rn analyzer is based on an electrostatic collection method involving the use of a PIN photodiode to separately detect a particles emitted from 218Po and 214Po released from the decay of 222Rn in a hemispheric air-sample chamber. The response of the 222Rn analyzer with respect to the applied voltage, chamber volume size, and sample flow rate is investigated to determine the appropriate measuring conditions. With this instrument, the detection limits have improved to 0.16-0.20 Bq m-3 for 1 h. The new 222Rn analyzer shows several technical advancements over the previous electrostatic collection methods, such as an improved detection limit, higher sensitivity, higher time-resolution analysis, and longer life. During the preliminary observational test, the 222Rn measuring system was able to detect the diurnal cycle in 222Rn resulting from the mixing of rapid vertical air in the surface boundary layer. At the Minamitorishima station located far from the continent, very small 222Rn peaks were clearly detected when long-range transport of polluted air masses from the Asian continent was observed at the station. We demonstrate that our compact 222Rn measuring system has the potential to be widely used for high time-resolution measurements of low-level 222Rn.
机译:已经开发出一种适用于各种大气观测的新型自动222Rn测量系统。该系统包括222Rn分析仪和空气采样单元,以及泵,干燥设备和过滤器。该222Rn分析仪的操作基于静电收集方法,该方法包括使用PIN光电二极管来分别检测从222Rn的衰变所释放的218Po和214Po发射的颗粒在半球形空气样品室中的颗粒。研究了222Rn分析仪相对于施加电压,反应室体积大小和样品流速的响应,以确定适当的测量条件。使用该仪器,在1小时内的检出限已提高到0.16-0.20 Bq m-3。新型222Rn分析仪显示出比以前的静电收集方法更先进的技术,例如改进的检测限,更高的灵敏度,更高的时间分辨率分析和更长的使用寿命。在初步观察测试期间,222Rn测量系统能够检测到222Rn的昼夜循环,这是由于表面边界层中快速垂直空气混合所致。在远离大陆的Minamitorishima站,当在该站观察到来自亚洲大陆的污染空气的长距离运输时,清晰地检测到了非常小的222Rn峰。我们证明了我们紧凑的222Rn测量系统具有被广泛用于低电平222Rn的高时间分辨率测量的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号