Background: The applicability and validity of many patient-reported outcome measures in the high-functioning population are not well understood. Purpose: To compare the psychometric properties of the modified Harris Hip Score (mHHS), the Hip Outcome Score activities of daily living subscale (HOS-ADL) and sports (HOS-sports), and the Lower Extremity Computerized Adaptive Test (LE CAT). The hypotheses was that all instruments would perform well but that the LE CAT would show superiority psychometrically because a combination of CAT and a large item bank allows for a high degree of measurement precision. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Data were collected from 472 advanced-age, active participants from the Huntsman World Senior Games in 2012. Validity evidences were examined through item fit, dimensionality, monotonicity, local independence, differential item functioning, person raw score to measure correlation, and instrument coverage (ie, ceiling and floor effects), and reliability evidences were examined through Cronbach alpha and person separation index. Results: All instruments demonstrated good item fit, unidimensionality, monotonicity, local independence, and person raw score to measure correlations. The HOS-ADL had high ceiling effects of 36.02%, and the mHHS had ceiling effects of 27.54%. The LE CAT had ceiling effects of 8.47%, and the HOS-sports had no ceiling effects. None of the instruments had any floor effects. The mHHS had a very low Cronbach alpha of 0.41 and an extremely low person separation index of 0.08. Reliabilities for the LE CAT were excellent and for the HOS-ADL and HOS-sports were good. Conclusion: The LE CAT showed better psychometric properties overall than the HOS-ADL, HOS-sports, and mHHS for the senior population. The mHHS demonstrated pronounced ceiling effects and poor reliabilities that should be of concern. The high ceiling effects for the HOS-ADL were also of concern. The LE CAT was superior in all psychometric aspects examined in this study. Future research should investigate the LE CAT for wider use in different populations.
机译:背景:在高功能人群中,许多患者报告的结局指标的适用性和有效性尚不十分清楚。目的:比较改良的哈里斯髋关节评分(mHHS),日常生活量表(HOS-ADL)和运动(HOS-sports)的髋关节成果评分活动以及下肢计算机自适应测验(LE CAT)的心理测量特性。假设是所有仪器性能都很好,但是LE CAT在心理上会显示出优越性,因为CAT和大型项目库的组合可以实现很高的测量精度。研究设计:队列研究(诊断);证据级别,方法2.方法:数据收集自2012年亨斯迈世界老年运动会的472位年龄较大,活跃的参与者。通过项目拟合,维度,单调性,局部独立性,差异项目功能,人员原始评分来检验有效性证据。通过Cronbach alpha和人员分离指数检查了相关性,仪器覆盖范围(即天花板和地板的影响)以及可靠性证据。结果:所有仪器均显示出良好的项目拟合度,一维性,单调性,局部独立性以及用于测量相关性的人员原始评分。 HOS-ADL的上限效应为36.02%,mHHS的上限效应为27.54%。 LE CAT的天花板效应为8.47%,而居屋运动没有天花板效应。没有一种乐器有任何地板效应。 mHHS的Cronbachα值非常低,为0.41,人员分离指数非常低,为0.08。 LE CAT的可靠性非常好,HOS-ADL和HOS-sports的可靠性也很好。结论:LE CAT在老年人群中总体表现出比HOS-ADL,HOS-sports和mHHS更好的心理测量特性。 mHHS表现出明显的天花板效应和较差的可靠性,值得关注。居屋低密度脂蛋白的高天花板效应也值得关注。在这项研究中,LE CAT在所有心理测量方面均表现出色。未来的研究应该研究LE CAT,以便在不同人群中更广泛地使用。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号