Enclosing the Air Gap from Formalin Delivery Tubing to Vertical-Flow Fish Egg Incubators Does Not Decrease Aerosolized Formaldehyde Levels

机译:封闭从福尔马林输送管到垂直流鱼卵培养箱的气隙不会降低气溶胶化的甲醛水平

获取原文
       

摘要

Formalin treatments are frequently used to control water molds during hatchery incubation of salmonid eggs, creating potential occupational safety and health issues. This investigation evaluated the use of a novel technique to enclose the air gap from formalin treatment tubes to 16-tray vertical-flow incubation stacks. Standard formalin treatments of 1667 mg/L for 15-minutes were administered to one, three, or five stacks, both with, and without air gap enclosures. Enclosing the air gap did not significantly reduce aerosolized formaldehyde levels. Even during the treatment of five incubation stacks when formalin amounts were the greatest, mean (SE) peak airborne formaldehyde levels were 1.6 (0.2) mg/L and 1.5 (0.2) ? mg/L, either with or without air gap enclosure, ? respectively. The failure of air gap enclosure indicates other techniques are required to decrease aerosolized formaldehyde during formalin treatments of fish eggs in vertical-flow incubators.
机译:在鲑鱼卵孵化场孵化期间,福尔马林处理经常用于控制水霉,从而产生潜在的职业安全和健康问题。这项研究评估了使用一种新技术来封闭从福尔马林处理管到16盘垂直流培养箱的气隙。将1667 mg / L的标准福尔马林处理液处理1分钟,3或5个堆栈,每次15分钟,无论有无气密外壳。封闭气隙并没有显着降低雾化甲醛水平。即使在五个培养皿中福尔马林含量最大的处理过程中,空气中甲醛的平均(SE)峰值甲醛含量仍为1.6(0.2)mg / L和1.5(0.2)? mg / L,带或不带气密外壳,?分别。气隙封闭的失败表明在垂直流培养箱中对鱼卵进行福尔马林处理期间,需要其他技术来减少雾化甲醛。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号