...
首页> 外文期刊>Natural science >Assessing gestational age of babies: Performance of obstetric ultrasound scan compared to that from the combination of Naegle’s rule and Dubowitz score in the 21st century
【24h】

Assessing gestational age of babies: Performance of obstetric ultrasound scan compared to that from the combination of Naegle’s rule and Dubowitz score in the 21st century

机译:评估婴儿的胎龄:与21世纪Naegle规则和Dubowitz得分相结合的产科超声扫描性能

获取原文

摘要

Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS; and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS.
机译:背景:一些研究人员建议,如果将Naegle规则(NR)和Dubowitz评分(DS)结合起来,则其性能可能优于产科超声扫描(USS)。其他人仍然认为,相对于NR规则和DS结合使用产科USS评估婴儿的胎龄(GA)仍然有效。目的:利用产科USS,NR和DS确定和比较婴儿的GA;并提供21世纪产科USS的相关公共卫生信息。方法:使用系统随机抽样选择受试者,并使用产科USS,NR和DS确定婴儿的GA。美国芝加哥伊利诺伊州社会科学统计软件包(SPSS)统计软件版本16被用于所有数据分析。结果:研究了八十五对母婴。四十四名婴儿(52%)是男性,而四十一名婴儿(48%)是女性。术语(64%)(75%)在95%CI(2.89 -3.14)kg时的平均(SD)BW为3.02(0.59)。在95%CI(38.14-?38.85)周时,婴儿的总体平均GA为38.49(2.89)。使用产科USS,NR和DS的平均GA在95 %CI(38.14-?38.99)下为38.52(1.98),在95 %CI(37.20-?38.99)下为38.09(4.13)和在95 %CI下为38.82(2.02) %CI(38.39-?39.26),但这些均值的比较并不显着(p = 0.256)。在95%CI(37.96-?38.95),通过NR和DS得出的合并平均GA为38.46(3.26)。将该平均值与产科USS获得的平均GA进行比较也不显着(p = 0.885)。结论:产科USS,NR和DS的GA评估均是可靠的,并且相对于NR和DS组合,产科USS的效果良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号