Can initial diagnostic PET-CT aid to localize tumor bed in breast cancer radiotherapy: feasibility study using deformable image registration

机译:初步诊断性PET-CT能否帮助定位乳腺癌放射治疗中的肿瘤床:使用可变形图像配准的可行性研究

获取原文
           

摘要

Background Localization of the tumor bed of breast cancer is crucial for accurate planning of boost irradiation. Lumpectomy cavity and surgical clips provide localizing information about tumor bed. However, defining the tumor bed is often difficult because of presence of unclear lumpectomy cavity and lack of certain information such as absence of surgical clips. In the present study, we evaluated the feasibility of initial diagnostic PET-CT in localization of the tumor bed using deformable image registration (DIR). Methods We selected twenty-five patients who had an initial diagnostic PET-CT performed and underwent breast-conserving surgery with surgical clips in tumor bed. In every individual patient, two target volumes were separately delineated on planning CT; 1) target volume based on surgical clips with a margin of 1 cm (TVclip) and 2) tumor volume based on 90% of maximum SUV on PET-CT registered by DIR (TVPET). The percent of TVPET in TVclip (Vin) was calculated and distance between center points of two volumes (Dcenter) was also measured. Results Mean Dcenter between two volumes was 1.4 cm (range, 0.33 – 2.53). Mean Vin was 94.8% (range, 60.9-100) and 100% in 18 out of 25 patients. When compared to the center of TVclip, the center of TVPET tended to be located posteriorly (mean 0.3 cm, standard deviation 0.6), laterally (mean 0.3 cm, standard deviation 0.8) and inferiorly (mean 0.4 cm, standard deviation 0.9). Conclusion Initial diagnostic PET-CT can be one of the possible references to localize the tumor bed in breast cancer radiotherapy.
机译:背景乳腺癌肿瘤床的定位对于增强辐射的准确计划至关重要。乳房切除术腔和手术夹可提供有关肿瘤床的局部信息。然而,由于存在不清晰的肿块切除腔和缺乏某些信息(例如缺少手术夹),通常难以确定肿瘤床。在本研究中,我们使用可变形图像配准(DIR)评估了初步诊断PET-CT在肿瘤床定位中的可行性。方法我们选择了25例进行了初步诊断性PET-CT的患者,并在肿瘤床上用手术夹进行了保乳手术。在每位患者中,计划CT分别划定了两个目标体积。 1)基于1 cm切缘的手术夹的目标体积(TV clip )和2)基于DIR登记的PET-CT上最大SUV的90%的肿瘤体积(TV PET )。计算TV clip 中TV PET 的百分比(V in ),并计算两个体积的中心点之间的距离(D center < / sub>)。结果两个体积之间的平均D center 为1.4 cm(范围0.33 – 2.53)。 25位患者中有18位的平均V in 为94.8%(范围60.9-100)和100%。与TV Clip 的中心相比,TV PET 的中心倾向于位于后方(平均0.3厘米,标准偏差0.6),侧面(平均0.3厘米,标准)。偏差0.8)和劣等(平均0.4厘米,标准偏差0.9)。结论初步诊断性PET-CT可能是乳腺癌放射治疗中定位肿瘤床的可能参考之一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号