首页> 外文期刊>Radiation oncology >Evaluation of transperineal ultrasound imaging as a potential solution for target tracking during hypofractionated radiotherapy for prostate cancer
【24h】

Evaluation of transperineal ultrasound imaging as a potential solution for target tracking during hypofractionated radiotherapy for prostate cancer

机译:会阴超声成像作为前列腺癌超分割放疗过程中靶点追踪的潜在解决方案的评估

获取原文
           

摘要

Emerging hypofractionated prostate radiotherapy regimens require solutions for accurate target tracking during beam delivery. The goal of this study is to evaluate the performance of the Clarity ultrasound monitoring system for prostate motion tracking. Five prostate patients underwent continuous perineum ultrasound imaging during their daily treatments. Initial absolute 3D positions of fiducials implanted in the prostate were estimated from the KV images. Fiducial positions in MV images acquired during beam delivery were compared with predicted positions based on Clarity 3D tracking. The uncertainty in the comparison results was evaluated in a phantom validation study. Continuous real-time ultrasound motion tracking was recorded in 5 patients and 167 fractions for overall of 39.7?h. Phantom validation of the proposed procedure demonstrated that predicted and observed fiducial positions agree within 1.1?mm. In patients agreement between predicted and actual fiducial positions varied between 1.3?mm and 3.3?mm. On average ultrasound tracking reduced the maximum localization error in patients by 20% on average. With the motion corrected, the duration prostate beyond 1?mm from its initial treatment position can be reduced from 37 to 22% of the total treatment time. Real-time ultrasound tracking reduces uncertainty in prostate position due to intra-fractional motion. IRB Protocol #27372 . Date of registration of trial: 12/17/2013.
机译:新兴的超分割前列腺放射治疗方案需要解决方案,以在束传输过程中进行精确的目标跟踪。这项研究的目的是评估用于前列腺运动跟踪的Clarity超声监测系统的性能。五名前列腺患者在日常治疗中接受连续会阴超声检查。从KV图像估计植入在前列腺中的基准的初始绝对3D位置。根据Clarity 3D跟踪,将在束传输过程中获取的MV图像中的基准位置与预测位置进行了比较。在幻像验证研究中评估了比较结果的不确定性。在5例患者中进行了连续实时超声运动跟踪,记录了167个分数,总时长为39.7?h。拟议程序的幻像验证表明,预测和观察到的基准位置在1.1?mm之内一致。在患者中,预计基准位置与实际基准位置之间的一致性在1.3?mm和3.3?mm之间变化。平均而言,超声跟踪可将患者的最大定位误差平均降低20%。校正运动后,从初始治疗位置开始超过1?mm的前列腺时间可以从总治疗时间的37%减少到22%。实时超声跟踪减少了由于小部分运动引起的前列腺位置的不确定性。 IRB协议#27372。试用版的注册日期:2013年12月17日。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号