首页> 外文期刊>Revista Argentina de Cardiologia >Evaluación del comportamiento del intervalo desde el inicio del QRS al inicio de la onda de pulso radial y carotídeo con el resultado del tilt test
【24h】

Evaluación del comportamiento del intervalo desde el inicio del QRS al inicio de la onda de pulso radial y carotídeo con el resultado del tilt test

机译:用倾斜测试的结果评估从QRS起点到径向和颈动脉脉搏波起点的间隔的行为

获取原文

摘要

Background The tilt test (TT) is a diagnostic tool used to evaluate autonomic function in patients with syncope. However, as TT has a high rate of false positive results and the duration of the test is long, new strategies are emerging. A device developed in Argentina allowed establishing a non-invasive, reproducible and reliable method to measure pulse wave velocity in the carotid and radial arteries during a conventional TT and to determine its likelihood to predict the result of the test. Objective To assess the usefulness of time delay of the pulse waveform from the onset of the QRS complex in order to predict the result of the tilt test. Material and Methods We conducted an observational study on consecutive patients with syncope referred to the tilt test laboratory. During the test blood pressure, heart rate and carotid and radial pulse waves were recorded simultaneously with a specially designed polygraph. Univariate and multivariate analyses were performed to assess the ability of time delay of the pulse waveform from the onset of the QRS complex to predict the result of the TT. This ability was evaluated with the analysis of ROC curves. Results A total of 43 patients were included; 24 (55.8%) were women. The TT was positive in 18 patients (11 women). Univariate analysis determined that changes in systolic blood pressure (p=0.02) and diastolic blood pressure (p<0.01) measured at 10 minutes, the use of ACEI/ARB (p=0.01) and time delay of the carotid pulse wave (p<0.01) were related to the result of the TT. At multivariate analysis, only time delay of the carotid pulse wave was a significant predictor of the result (p=0.036). The C statistic of the time delay of the carotid pulse wave was 0.88 (95% CI 0.76 to 0.99). Conclusions Measurement of the time delay or the carotid pulse wave at 5 minutes is an independent predictor of the result of the TT, allowing a correct classification in 88% of patients before the development of symptoms.
机译:背景技术倾斜测试(TT)是一种诊断工具,用于评估晕厥患者的自主神经功能。但是,由于TT假阳性率很高,而且测试时间长,因此出现了新的策略。在阿根廷开发的设备允许建立一种非侵入性,可再现且可靠的方法,以在常规TT期间测量颈动脉和radial动脉的脉搏波速度,并确定其预测测试结果的可能性。目的从QRS波群开始评估脉冲波形的时间延迟的有用性,以预测倾斜测试的结果。材料和方法我们对倾斜测试实验室的连续晕厥患者进行了观察性研究。在测试过程中,使用专门设计的测谎仪同时记录血压,心率,颈动脉和径向脉搏波。进行了单因素和多因素分析,以评估从QRS波群开始起的脉搏波形的时间延迟能力,以预测TT结果。通过分析ROC曲线评估了该能力。结果共纳入43例患者。 24名(55.8%)是女性。 18名患者(11名妇女)的TT阳性。单因素分析确定在10分钟时测得的收缩压(p = 0.02)和舒张压(p <0.01)的变化,ACEI / ARB的使用(p = 0.01)和颈动脉脉搏波的延迟(p <0.01) 0.01)与TT结果相关。在多变量分析中,只有颈动脉搏动波的时间延迟是结果的重要预测指标(p = 0.036)。颈动脉搏动波的时延的C统计量是0.88(95%CI 0.76至0.99)。结论5分钟时延或颈动脉搏动波的测量是TT结果的独立预测因素,可以在出现症状之前对88%的患者进行正确分类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号