首页> 外文期刊>Revista Brasileira de Cineantropometria & Desempenho Humano >Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
【24h】

Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers

机译:训练有素的游泳者的肘部屈肌和肘伸肌的等距和等速峰值扭矩的可靠性

获取原文
           

摘要

Abstract In this study, it was hypothesized that the peak torque reliability would depend on the type of muscular action. The aim of this study was to analyze and to compare the reliability of isometric peak torque (IPT) and isokinetic peak torque at speeds of 60o.s-1 and 180o.s-1 (CPT60 and CPT180, respectively) of elbow flexors (EF) and elbow extensors (EE) muscles in trained swimmers. Twenty trained male swimmers (23 ± 5 years) performed the following protocols in different days: 1) Familiarization to isokinetic dynamometer; 2) Two maximal isometric voluntary contractions to determine IPT and five maximal concentric isokinetic contractions at 60o.s-1and 180o.s-1 to determine CPT60 and CPT180, respectively (T1). The tests for IPT, CPT60 and CPT180 determination were performed in random order, and; 3) The same tests were performed in the same order of those performed on the second day (T2). There was no significant difference of IPT, CPT60 and CPT180 values between T1 and T2. Higher intraclass correlation coefficient (ICC) and lower typical error (TE) of IPT (ICC - 0.87 - 0.92; TE - 6.9 - 10.9%) in relation to CPT60 (CCI - 0.66 - 0.79, TE - 12.0 - 12.8%) and CPT180 (ICC - 0.85 - 0.85; TE - 8.5 - 9.2%) was observed. Based on these results, it could be concluded that the peak torque of EF and EE muscles presents moderate to excellent reliability, and can be influenced by the type of muscular action performed by trained swimmers.
机译:摘要在这项研究中,假设峰值扭矩可靠性取决于肌肉动作的类型。本研究的目的是分析和比较肘屈肌(EF)在60o.s-1和180o.s-1(分别为CPT60和CPT180)速度下的等距峰值扭矩(IPT)和等速峰值扭矩的可靠性)和受过训练的游泳者的肘伸肌(EE)。二十名受过训练的男性游泳者(23±5岁)在不同的日期执行以下操作:1)熟悉等速测功机; 2)两个最大等距自主收缩确定IPT,五个最大同心等速收缩分别在60o.s-1和180o.s-1处确定CPT60和CPT180(T1)。 IPT,CPT60和CPT180测定的测试以随机顺序进行; 3)以与第二天(T2)相同的顺序进行相同的测试。 T1和T2之间的IPT,CPT60和CPT180值没有显着差异。相对于CPT60(CCI-0.66-0.79,TE-12.0-12.8%)和CPT180,较高的类内相关系数(ICC)和较低的IPT典型误差(TE)(ICC-0.87-0.92; TE-6.9-10.9%)观察到(ICC-0.85-0.85; TE-8.5-9.2%)。根据这些结果,可以得出结论,EF和EE肌肉的峰值扭矩表现出中等至极好的可靠性,并且受训练有素的游泳者执行的肌肉动作类型的影响。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号