...
首页> 外文期刊>Remote Sensing >Evaluating Eight Global Reanalysis Products for Atmospheric Correction of Thermal Infrared Sensor—Application to Landsat 8 TIRS10 Data
【24h】

Evaluating Eight Global Reanalysis Products for Atmospheric Correction of Thermal Infrared Sensor—Application to Landsat 8 TIRS10 Data

机译:评估八种用于热红外传感器的大气校正的全球再分析产品-在Landsat 8 TIRS10数据中的应用

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Global reanalysis products have been widely used for correcting the atmospheric effects of thermal infrared data, but their performances have not been comprehensively evaluated. In this paper, we evaluate eight global reanalysis products (NCEP/FNL; NCEP/DOE Reanalysis2; MERRA-3; MERRA-6; MERRA2-3; MERRA2-6; JRA-55; and ERA-Interim) commonly used in the atmospheric correction of Landsat 8 TIRS10 data by referencing global radiosonde observations collected from 163 stations. The atmospheric parameters (atmospheric transmittance, upward radiance, and downward radiance) simulated with MERRA-6 and ERA-Interim were accurate than those simulated with other reanalysis products for different water vapor contents and surface elevations. When global reanalysis products were applied to retrieve land surface temperature (LST) from simulated Landsat 8 TIRS10 data, ERA-Interim and MERRA-6 were accurate than other reanalysis products. The overall LST biases and RMSEs between the retrieved LSTs and LSTs that were used to generate the top-of-atmosphere radiances were less than 0.2 K and 1.09 K, respectively. When eight reanalysis products were used to estimate LSTs from thirty-two Landsat 8 TIRS10 images covering the Heihe River basin in China, the various reanalysis products showed similar validation accuracies for LSTs with low water vapor contents. The biases ranged from 0.07 K to 0.24 K, and the STDs (RMSEs) ranged from 1.93 K (1.93 K) to 2.02 K (2.04 K). Considering the above evaluation results, MERRA-6 and ERA-Interim are recommended for thermal infrared data atmospheric corrections.
机译:全球再分析产品已被广泛用于校正热红外数据对大气的影响,但尚未对其性能进行全面评估。在本文中,我们评估了大气中常用的八种全球再分析产品(NCEP / FNL; NCEP / DOE Reanalysis2; MERRA-3; MERRA-6; MERRA2-3; MERRA2-6; JRA-55; ERA-Interim)通过参考从163个台站收集的全球无线电探空仪观测值,对Landsat 8 TIRS10数据进行校正。对于不同的水蒸气含量和表面高度,使用MERRA-6和ERA-Interim模拟的大气参数(大气透射率,向上辐射和向下辐射)比使用其他再分析产品模拟的大气参数准确。当使用全球再分析产品从模拟的Landsat 8 TIRS10数据中检索地表温度(LST)时,ERA-Interim和MERRA-6比其他再分析产品更准确。用来生成大气顶辐射的检索到的LST和LST之间的总LST偏差和RMSE分别小于0.2 K和1.09K。当使用八种再分析产品从覆盖中国黑河流域的32幅Landsat 8 TIRS10图像中估算LST时,各种再分析产品显示出对低水蒸气含量的LST的相似验证准确性。偏置范围为0.07 K至0.24 K,STD(RMSE)范围为1.93 K(1.93 K)至2.02 K(2.04 K)。考虑到上述评估结果,建议将MERRA-6和ERA-Interim用于热红外数据大气校正。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号