首页> 外文期刊>Radiology Research and Practice >Double Bolus Application in TWIST-MR-Angiography of the Cervical Arteries
【24h】

Double Bolus Application in TWIST-MR-Angiography of the Cervical Arteries

机译:TWIST-MR颈动脉造影中的双腔应用

获取原文
       

摘要

Purpose. The aim of the present work was to test the feasibility of the time-resolved MR-angiography (TWIST-MRA) of cervical arteries using double bolus injection.Material and Methods. TWIST-MRA with a temporal resolution of 8.4 seconds for each frame and a spatial resolution with a voxel size of0.61×0.58×0.8 mm3was performed in 24 patients. A biphasic bolus injection protocol was used with the second injection being started 21 seconds after the first contrast dye bolus. Diagnostic image quality was rated according to a 4-point scale.Results. In 12 patients (50%) no clear separation between the cervical venous and arterial vessels was evident after the first bolus injection. Using TWIST-MRA data acquired after the second bolus a sufficient diagnostic image quality (rating≥3, mean 3.5) could be obtained in 22 of 24 patients (92%).Discussion. The double bolus injection protocol using TWIST-MRA allows for very good separation of the cervical arteries.
机译:目的。本工作的目的是检验使用双剂量推注进行颈动脉的时间分辨MR血管造影(TWIST-MRA)的可行性。材料和方法。 TWIST-MRA在24例患者中进行了时间分辨率为每帧8.4秒和体素大小为0.61×0.58×0.8?mm3的空间分辨率。使用双相推注注射方案,第二次注射在第一个对比染料推注之后21秒开始。诊断图像质量根据4分制进行评分。第一次推注后,有12例患者(50%)颈静脉和动脉血管之间没有明显分离。使用第二次推注后获得的TWIST-MRA数据,可以在24例患者中的22例(92%)中获得足够的诊断图像质量(评级≥3,平均3.5)。使用TWIST-MRA的双推注方案可以很好地分离颈动脉。