首页> 外文期刊>Research journal of applied science, engineering and technology >The Use of Simulation Modelling for Optimisation of Phosphorus Removal in Sewage Treatment under Varying Influent Loading
【24h】

The Use of Simulation Modelling for Optimisation of Phosphorus Removal in Sewage Treatment under Varying Influent Loading

机译:模拟模型在污水负荷变化下污水处理中除磷效果的优化

获取原文
           

摘要

A validated ASM2 model (STOAT) for the Changzhou WWTP was used to evaluate operational problems encountered in most wastewater treatment plants, during the transitional period from winter to summer. Favourable operating conditions which can achieve both TN and TP effluent concentrations under varying influent loading without the use of either chemical polishing or external carbon sources were established. Further, the use of 1.5 h wastage pump run time and 4.5 h cycle time was found better than the 3 h wastage pump run time and the 6 h cycle time as practiced in most WWTPs, as the latter is sufficient to allow second TP release, whereas the former is found to improve effluent TP by approximately 73%. The model was applied to troubleshoot another WWTP successfully. The finding in this study will improve the management of wastewater treatment plants for better and consistent effluent quality at a reduced capital cost.
机译:经过验证的常州污水处理厂ASM2模型(STOAT)用于评估从冬季到夏季过渡期大多数污水处理厂遇到的运营问题。建立了可以在不使用化学抛光或使用外部碳源的情况下,在变化的进水量下达到TN和TP废水浓度的良好操作条件。此外,发现在大多数污水处理厂中,使用1.5小时的浪费泵运行时间和4.5小时的循环时间要比大多数污水处理厂的3小时的浪费泵运行时间和6小时的循环时间更好,因为后者足以允许第二个TP释放,而前者可将废水的总磷提高约73%。该模型已成功用于对另一个WWTP进行故障排除。这项研究的发现将以较低的投资成本改善废水处理厂的管理,以提高废水质量并保持一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号