...
首页> 外文期刊>Radiologia Brasileira >Comparison of Cartesian and radial acquisition on short-tau inversion recovery (STIR) sequences in breast MRI
【24h】

Comparison of Cartesian and radial acquisition on short-tau inversion recovery (STIR) sequences in breast MRI

机译:乳腺MRI中短头倒置恢复(STIR)序列的笛卡尔和径向获取的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objective: The purpose of this study was to compare two short-tau inversion recovery (STIR) sequences, Cartesian and radial (BLADE) acquisitions, for breast magnetic resonance imaging (MRI) examinations. Materials and Methods: Ninety-six women underwent 1.5 T breast MRI exam (48 Cartesian and 48 BLADE). Qualitative analysis including image artifacts, image quality, fat-suppression, chest-wall depiction, lesion detection, lymph node depiction and overall impression were evaluated by three blinded readers. Signal to noise ratios (SNRs) were calculated. Cronbach's alpha test was used to assess inter-observer agreement. Subanalyses of image quality, chest-wall depiction and overall impression in 15 patients with implants and image quality in 31 patients with clips were correlated using Pearson test. Wilcoxon rank sum test and t -test were performed. Results: Motion artifacts were present in 100% and in 0% of the Cartesian and the BLADE exams, respectively. Chemical-shift artifacts were present in 8% of the Cartesian exams. Flow artifacts were more frequent on BLADE. BLADE sequence was statistically superior to Cartesian for all qualitative features ( p < 0.05) except for fat-suppression ( p = 0.054). In the subanalysis, BLADE was superior for implants and clips ( p < 0.05). SNR was statistically greater for BLADE (48.35 vs. 16.17). Cronbach ranged from 0.502 to 0.813. Conclusion: BLADE appears to be superior to Cartesian acquisition of STIR imaging as measured by improved image quality, fewer artifacts, and improved chest wall and lymph node depiction.
机译:目的:本研究的目的是比较两种短τ倒置恢复(STIR)序列,即笛卡尔和放射状(BLADE)采集,以进行乳房磁共振成像(MRI)检查。材料和方法:96名妇女接受了1.5 T乳腺MRI检查(48次笛卡尔和48次BLADE)。由三位不知情的读者评估了定性分析,包括图像伪影,图像质量,脂肪抑制,胸壁描绘,病变检测,淋巴结描绘和总体印象。计算信噪比(SNR)。克伦巴赫(Cronbach)的alpha测试用于评估观察员之间的共识。使用Pearson检验,对15例植入物患者的图像质量,胸壁描述和总体印象进行亚分析,并对31例有夹子的患者的图像质量进行相关分析。进行了Wilcoxon秩和检验和t检验。结果:笛卡尔和布莱德考试中分别存在100%和0%的运动伪影。 8%的笛卡尔考试中存在化学位移伪影。流工件在BLADE上更为常见。在所有定性特征方面,除脂肪抑制(p = 0.054)外,BLADE序列在统计学上均优于笛卡尔坐标系(p <0.05)。在亚分析中,BLADE优于植入物和夹子(p <0.05)。对于BLADE,SNR的统计值更高(48.35 vs. 16.17)。 Cronbach的范围为0.502至0.813。结论:通过改善图像质量,减少伪影以及改善胸壁和淋巴结描绘,BLADE似乎优于笛卡尔采集的STIR成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号