首页> 外文期刊>Latin American Journal of Solids and Structures >Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections
【24h】

Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections

机译:螺栓固定端板和螺栓法兰板连接的实验研究

获取原文
获取外文期刊封面目录资料

摘要

Abstract This paper describes the experimental performance of the bolted stiffened end-plate (BSEP) and bolted flange-plate (BFP) connections using European hot-rolled profiles and built-up profiles. Four connections are designed and constructed according to FEMA-350 and are performed under cyclic loading. The influence of using different member profiles (European profiles and built-up profiles) in both the BSEP and BFP connections are examined. The obtained test results, including failure modes, hysteretic curves, ultimate moment and rotation values and panel zone extensions were reported and the performance of different connections is compared. It was found out, based on the obtained test results, that using hot-rolled or built-up profiles in the connection does not affect its global behavior.
机译:摘要本文介绍了使用欧洲热轧型材和组合型材的螺栓连接的加强端板(BSEP)和螺栓连接的法兰板(BFP)的实验性能。根据FEMA-350设计和构造了四个连接,并在循环载荷下执行。研究了在BSEP和BFP连接中使用不同的成员配置文件(欧洲配置文件和内置配置文件)的影响。报告了获得的测试结果,包括破坏模式,磁滞曲线,极限力矩和旋转值以及面板区域扩展,并比较了不同连接的性能。根据获得的测试结果发现,在连接中使用热轧或组合式配置文件不会影响其全局行为。