Simultaneous 13 C/ 14 C dual isotope breath test measurement of gastric emptying of solid and liquid in normal subjects and patients: comparison with scintigraphy

机译:正常受试者和患者同时进行13 C / 14 C双同位素呼吸试验测量固体和液体的胃排空:与闪烁显像的比较

获取原文
       

摘要

BACKGROUND: To develop a simple method for simultaneous solid and liquid gastric emptying assessment using a dual isotope labelled breath test. MATERIAL AND METHODS: 13 patients were given 100 g ground beef labelled with 25 MBq 99m Tc sulphur colloid and 74 KBq 14 C octanoic acid, and 150 ml 10% glucose drink labelled with 8 MBq 67 Ga citrate and 150 mg 13 C acetate. 10 normal volunteers were given the same test meals but labelled with 14 C and 13 C only. Breath was collected at baseline and regularly for 4 hours. The 14 CO 2 and 13 CO 2 activity was measured with liquid scintillation counting and mass spectroscopy. The times to maximum 14 CO 2 and 13 CO 2 , were determined. Comparison was made between times to maximum 14 CO 2 with scintigraphic retention of 99m Tc at 100 minutes and times to maximum 13 CO 2 with the scintigraphic half-clearance time of 67 Ga. RESULTS: For the solid meal, the times to maximum 14 CO 2 were: 60–120 minutes in the 8 patients with normal gastric emptying of 99m Tc; 75–145 minutes for the 10 healthy volunteers; 75–180 minutes for the remaining 5 patients with abnormal gastric emptying of 99m Tc. There was a weak but significant correlation (r = 0.56, p 14 CO 2 and gastric retention of 99m Tc at 100 minutes. For the liquid meal, times to maximum 13 CO 2 were: 20–35 minutes for the 4 with normal gastric emptying of 67 Ga; 15–40 minutes for the 10 healthy volunteers; 20–75 minutes for the remaining 9 patients with abnormal gastric emptying of 67 Ga. There was a strong and significant correlation (r = 0.88, p 13 CO 2 and gastric half-clearance time of 67 Ga. CONCLUSIONS: Breath tests utilising test meals labelled with *C isotopes are valid alternatives to scintigraphic studies using 99m Tc and 67 Ga for the simultaneous assessment of gastric emptying of solids and liquids.
机译:背景:开发一种使用双同位素标记呼气试验同时进行固液和液胃排空评估的简单方法。材料与方法:13例患者接受100 g碎牛肉,标记有25 MBq 99m Tc硫胶体和74 KBq 14 C辛酸,以及150 ml 10%葡萄糖饮料,标记有8 MBq 67 Ga柠檬酸盐和150 mg 13 C乙酸盐。给10名正常志愿者提供相同的测试餐,但仅标注14 C和13C。在基线收集呼吸并定期呼吸4小时。用液体闪烁计数和质谱法测量14 CO 2和13 CO 2活性。确定达到最大14 CO 2和13 CO 2的时间。在100分钟的闪烁显像保留时间为99m Tc的情况下,最高14 CO 2的时间与闪烁显像半清除时间为67 Ga的最高13 CO 2的时间之间进行了比较。 2例是:8例正常胃排空99m Tc的患者60-120分钟; 10名健康志愿者需要75-145分钟;其余5例胃排空异常99m Tc的患者75-180分钟。两者之间存在弱但显着的相关性(r = 0.56,p 14 CO 2和在100分钟时胃retention留为99m Tc。对于流食,至最大13 CO 2的时间为:正常胃排空的4个人的20-35分钟为67 Ga; 10名健康志愿者为15-40分钟;其余9名胃排空异常为67 Ga的患者为20-75分钟。二者之间存在强而显着的相关性(r = 0.88,p 13 CO 2和胃半数清除时间为67 Ga。结论:采用* C同位素标记的试验餐进行的呼气试验是使用99m Tc和67 Ga进行闪烁显像的同时替代评估胃排空固体和液体的有效方法。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号