Automation of Ischemia Modified Albumin on Beckman Analyser

机译:在Beckman分析仪上自动化缺血修饰的白蛋白

获取原文
       

摘要

Introduction: Early markers for the diagnosis of acute myocardial ischemia are required before necrosis sets in. Ischemia-Modified Albumin (IMA) is one marker which has been shown to rise early before cell necrosis and has been found to be useful in the diagnosis of acute myocardial ischemia.Aim: The present study was taken up to evaluate the assay of IMA levels using albumin cobalt binding method and to automate the method on Beckman Synchron DxC600 analyser.Materials and Methods: Seventy patient samples received in the clinical laboratory for biochemical analysis were used after analysis of the required parameters. Cobalt chloride (CoCl2) and Dithiothrietol (DTT) solutions in various concentrations were tested keeping one parameter constant at a time. Spectrum scan was performed, λ max was noted and absorbance measured at 5 min, 10 min, 15 min, 20 min, 25 min. After the method was established, within run, day to day precision, recovery and interference experiments were performed to test the method performanceResults: Experiments showed that CoCl2, corresponding to a concentration of 0.641 mmol/l and DTT corresponding to a concentration of 1.6207 mmol/l in the final reaction mixture gave the maximum absorbance at 470nm. The method was found to be linear upto an albumin concentration of 5.5g/dl. Intra-assay coefficient of variation (CV) and Inter-assay CV were 1% and 2.5% respectively. IMA test showed no interference for triglyceride concentration upto 443mg/dl, bilirubin concentrations upto 7.9mg/dl and haemoglobin upto 3g/dl. IMA analysis in paired serum and plasma showed values to be higher in serum compared to heparinised plasma.Conclusion: IMA assay can be performed on Beckman DxC 600 analyser. The sample analysis time is 10 minutes and the turn around time is short and thus acceptable. It can therefore be useful in patients with acute chest pain.
机译:简介:在坏死发作之前,需要早期标志物来诊断急性心肌缺血。缺血修饰白蛋白(IMA)是一种在细胞坏死之前就可以上升的标志物,被发现可用于诊断急性心肌缺血目的:本研究旨在利用白蛋白钴结合法评估IMA水平,并在贝克曼Synchron DxC600分析仪上自动化该方法。材料与方法:从临床实验室中收集了70份用于生化分析的患者样品。在分析所需参数后使用。测试了各种浓度的氯化钴(CoCl2)和二硫代三硫醇(DTT)溶液,同时保持一个参数不变。进行光谱扫描,记下λmax并在5分钟,10分钟,15分钟,20分钟,25分钟处测量吸光度。方法建立后,在日常运行中进行了精密度,回收率和干扰度试验,以测试方法的性能。结果:实验表明,CoCl2的浓度为0.641 mmol / l,DTT的浓度为1.6207 mmol / l。最终反应混合物中的l给出了在470nm下的最大吸光度。发现该方法是线性的,直至白蛋白浓度为5.5g / dl。批内变异系数(CV)和批间变异系数(CV)分别为1%和2.5%。 IMA测试显示,甘油三酸酯浓度高达443mg / dl,胆红素浓度高达7.9mg / dl和血红蛋白浓度高达3g / dl时均无干扰。配对的血清和血浆中的IMA分析显示,血清中的值高于肝素化血浆。结论:IMA分析可在Beckman DxC 600分析仪上进行。样品分析时间为10分钟,周转时间较短,因此可以接受。因此,它对患有急性胸痛的患者可能有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号