首页> 外文期刊>Materials Sciences and Applications >Modified Coated Copper Wire as a New Fiber for SPME-GC Analysis of Some Polycyclic Aromatic Hydrocarbons
【24h】

Modified Coated Copper Wire as a New Fiber for SPME-GC Analysis of Some Polycyclic Aromatic Hydrocarbons

机译:修饰涂层铜线作为SPME-GC分析某些多环芳烃的新型纤维

获取原文
   

获取外文期刊封面封底 >>

       

摘要

In this study for the first time, a novel copper Solid Phase Microextraction (SPME) fiber has been introduced for removal of naphthalene, phenanthrene and anthracene from aqueous solution. Copper was used as a solid support, which was at first coated by 3-mercaptopropyltrimethoxysi- lane. A stationary phase of oxidized multi walled carbon nanotube (MWCNTs)) was bonded to the surface of the copper wire. The developed SPME was characterized by IR and Scanning Electron Microscopy (SEM) and coupled to gas chromatography for separation of the analytes. Stability of the fiber, the effect of coating thickness and recovery time were optimized. The MWCNTs film thickness was about 5 μm which was perfect for a rapid mass transfer. The detection limits were at the range of 0.005 to 0.1 μg·L-1. The calibration curves were linear R2 > 0.9813 in the range of 0.01 to 5 μg·L-1. The method has been successfully applied for real samples with standard addition of 5 μL-1 of each sample. Stability study of the fiber to acid and alkali shows that it can be used for more than 50 times.
机译:在这项研究中,首次引入了新型铜固相微萃取(SPME)纤维,用于从水溶液中去除萘,菲和蒽。铜用作固体载体,首先将其涂覆3-巯基丙基三甲氧基硅烷。氧化多壁碳纳米管(MWCNT)的固定相结合到铜线的表面。所开发的SPME通过IR和扫描电子显微镜(SEM)进行表征,并与气相色谱仪耦合以分离分析物。优化了纤维的稳定性,涂层厚度和恢复时间的影响。 MWCNTs的膜厚约为5μm,非常适合快速传质。检出限为0.005〜0.1μg·L-1。校准曲线在0.01至5μg·L-1范围内为线性R2> 0.9813。该方法已成功应用于实际样品,每个样品标准加入5μL-1。纤维对酸和碱的稳定性研究表明它可以使用50次以上。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号