首页> 外文期刊>Neftegazovoe Delo >Capacitor bank evaluation for power factor improvement of an industrial plant’s distribution network with non-linear load.
【24h】

Capacitor bank evaluation for power factor improvement of an industrial plant’s distribution network with non-linear load.

机译:电容器组评估,用于改善带有非线性负载的工厂配电网络的功率因数。

获取原文
           

摘要

The paper focuses on the capacitor bank evaluation problem for power factor improvement of an industrial plant’s distribution network containing non-linear load. The problem is important due to large scale integration of power electronics into electrical supply systems of industrial plants including oil and gas enterprises.It is shown that the choice of the capacitor bank depends on the current harmonic spectrum consideration. The estimation of the equivalent circuit for the whole current harmonic spectrum and for the first current harmonic only has been carried out with the use of the classical ways of electric circuit analysis. The network parameters with the capacitor banks installed are provided for the comparison.The conclusion of necessity to take the whole current harmonic spectrum into account for the capacitor bank evaluation is drawn
机译:本文重点研究电容器组评估问题,以改善包含非线性负载的工厂配电网络的功率因数。由于将功率电子器件大规模集成到包括石油和天然气企业在内的工业工厂的供电系统中,这一问题非常重要,这表明电容器组的选择取决于电流谐波频谱考虑因素。仅使用经典的电路分析方法,对整个电流谐波频谱和一次电流谐波的等效电路进行了估算。提供了安装了电容器组的网络参数进行比较。得出结论,必须考虑整个电流谐波频谱以进行电容器组评估

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号