首页> 外文期刊>Microbes and Environments >Assessment of Capacity to Capture DNA Aerosols by Clean Filters for Molecular Biology Experiments
【24h】

Assessment of Capacity to Capture DNA Aerosols by Clean Filters for Molecular Biology Experiments

机译:通过分子生物学实验用干净的过滤器评估捕获DNA气溶胶的能力

获取原文
       

摘要

Experimental contamination by exogenous DNA is a major issue in molecular biological studies for data quality and its management. We herein assessed DNA aerosols for the risk of contamination and tested the capacity of clean air filters to trap and remove DNA aerosols. DNA aerosols were generated by atomizing a DNA solution and introduced into a laminar flow clean air unit. Capture and detection performed upstream and downstream of the clean air unit showed that a significant fraction (>99.96%) of introduced molecules was trapped and removed by the filter. Although DNA aerosols appear to be an avoidable source of exogenous contamination, a clearer understanding and careful experimental procedures are needed in order to perform contamination-free, high-quality molecular biology experiments.
机译:外源DNA的实验污染是分子生物学研究中数据质量及其管理的主要问题。我们在此评估了DNA气雾剂的污染风险,并测试了清洁空气过滤器捕获和去除DNA气雾剂的能力。通过将DNA溶液雾化生成DNA气溶胶,并将其引入层流清洁空气单元中。在清洁空气装置的上游和下游进行的捕获和检测表明,大部分(> 99.96%)的引入分子被过滤器捕获和去除。尽管DNA气溶胶似乎是可避免的外源性污染源,但是为了进行无污染的高质量分子生物学实验,需要有更清晰的理解和仔细的实验​​程序。