Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle

机译:多回声迪克森方法与容积插值呼吸保持梯度回波磁共振成像在椎旁肌脂肪信号组分定量中的比较

获取原文
           

摘要

Objective To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. Materials and Methods Sixty patients with low back pain underwent MR imaging with a 1.5T scanner. FF mapping images automatically obtained using T2*-corrected Dixon technique with two (non-T2*-corrected), three, and six echoes, were compared with images from single-voxel MR spectroscopy at the paravertebral muscles on levels L4 through L5. FFs were measured directly by two radiologists, who independently drew the region of interest on the mapping images from the three sequences. Results A total of 117 spectroscopic measurements were performed either bilaterally (57 of 60 subjects) or unilaterally (3 of 60 subjects). The mean spectroscopic FF was 14.3 ± 11.7% (range, 1.9-63.7%). Interobserver agreement was excellent between the two radiologists. Lin's concordance correlation between the spectroscopic findings and all the imaging-based FFs were statistically significant ( p Conclusion T2*-corrected six-echo Dixon sequence would be a better option than two- or three-echo methods for noninvasive quantification of lumbar muscle fat quantification.
机译:目的评价与同时进行T2 *估计和校正同时进行的多回波狄克逊磁共振(MR)成像与未经T2 *校正的两回波相比是否能更准确地测量腰椎旁肌肉的脂肪信号分数(FF) Dixon或经T2 *校正的三回波Dixon,使用单体素MR光谱的FF测量作为参考标准。材料与方法60例腰背痛患者使用1.5T扫描仪进行MR成像。将使用T2 *校正的Dixon技术自动获得的FF映射图像与两个(未经T2 *校正的),三个和六个回波进行比较,并将其与来自L4至L5级椎旁肌的单体素MR光谱图像进行比较。 FF是由两位放射线医师直接测量的,他们分别从这三个序列的绘图图像上绘制了感兴趣的区域。结果总共进行了117次光谱测量,分别在双边(60个受试者中的57个)或单侧(60个受试者中的3个)进行。平均光谱FF为14.3±11.7%(范围为1.9-63.7%)。两位放射科医生之间的观察员之间的协议非常好。 Lin的光谱学发现与所有基于成像的FF之间的一致性相关性具有统计学显着性(p结论T2 *校正的六回波Dixon序列对于腰肌脂肪定量的无创定量比两回波或三回波方法更好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号