首页> 外文期刊>Modern Applied Science >Equivalent Resistance of 5×n-laddered Network
【24h】

Equivalent Resistance of 5×n-laddered Network

机译:5×n梯形网络的等效电阻

获取原文
           

摘要

The The basic structure of 5× n -step network was studied by matrix transform method. Thus, the resistances of both the infinite and finite network were obtained. In addition, the resistances of the finite 5× n -laddered network were measured experimentally by NI Multisim 10 when n equals to positive integer such as one,two,three ... ,and so on . It is found that the measured values of the equivalent resistances of finite 5× n -laddered networks are consistent with the calculated ones.
机译:通过矩阵变换的方法研究了5×n步网络的基本结构。因此,获得了无限和有限网络的电阻。另外,当n等于一,二,三...等正整数时,使用NI Multisim 10实验性地测量了有限的5×n梯形网络的电阻。发现有限的5×n梯形网络的等效电阻的测量值与计算值一致。