A constant-rate pumping test executed during 171 h in the Guarani Aquifer System (GAS) was used to determine its??respective hydraulic parameters and to test the existence of a drainage through an 84-m basalt layer (Serra Geral Aquitard),??and the underlying sediments of the Corumbata?- Formation. The test was prformed in a pumping well with hydraulic load??monitoring in two minucipalities of Ribeir?£o Preto (S?£o Paulo State, Brazil), located 10 km south of it. Results show a??lack of drainage, and the positioning of the piezometers, in two distinct directions relative to the pumping well, allowed to??infer the existence of anisotropy of the hydraulic conductivity. The calculated hydraulic parameters, after data correction??for the pumping wella??s partial penetration and for the aquifera??s anisotropy, are a hydraulic conductivity of 5,3x10 -6 m/s??and 8,1x10 -6 m/s, and storativity of 1,6 ?? 10 -3 e 8,4 ?? 10 -4 , respectively for piezometers PPE-1G and PPE-2G. Maximum??transmissivity, T x = 1,9 ?? 10 -3 m 2 /s, occurs along the N-S direction, and minimum transmissivity, T y ??= 1,2 ?? 10 -3 m 2 /s,??sits along the E-W direction. On the horizontal plane, the relation between maximum and minimum transmissivities is??1,55. Drawdown does not stabilize during pumping, indicating that leakage through the basalts and through Corumbata?-??Formation was not sufficient to compensate for the discharge, or is nonexistent.
机译:在瓜拉尼含水层系统(GAS)中进行了171小时的恒速抽水试验,以确定其相应的水力参数,并测试通过84米玄武岩层(Serra Geral Aquitard)的排水情况。以及Corumbata的底层沉积物-地层。该测试是在带有液压负载的抽油机中进行的,该抽油机在位于南部10公里的Ribeir?o Preto(巴西圣保罗州)的两个地方进行监控。结果表明没有排水,并且压力计在相对于抽油井的两个不同方向上的位置可以推断出水力传导率的各向异性。在对泵井的部分渗透率和含水层的各向异性进行数据校正后,计算出的水力参数分别为5,3x10 -6 m / s和8,1x10 -6 m / s,存储率为1,6 ?? 10 -3 e 8,4 ??压力计PPE-1G和PPE-2G分别为10 -4。最大透射率,T x = 1.9。 10 -3 m 2 / s,沿着N-S方向发生,最小透射率T y ?? = 1,2 ??。 10 -3 m 2 / s,沿E-W方向坐。在水平面上,最大透射率与最小透射率之间的关系为1.55。在抽水过程中,压降不能稳定,这表明通过玄武岩和Corumbata-β-地层的泄漏不足以补偿排放,或者不存在泄漏。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号