首页> 外文期刊>Membranes >Experimental Study of Fouling and Cleaning of Sintered Stainless Steel Membrane in Electro-Microfiltration of Calcium Salt Particles
【24h】

Experimental Study of Fouling and Cleaning of Sintered Stainless Steel Membrane in Electro-Microfiltration of Calcium Salt Particles

机译:钙盐颗粒电微滤过程中烧结不锈钢膜的结垢与清洗实验研究

获取原文
           

摘要

Sintered stainless steel (SSS) microfiltration membranes, which served as electrode directly, were used for the experiment of separating Alamin, a calcium salt and protein containing particles, found in dairy processing. Fouling and cleaning of the SSS membranes under the application of an external electric field were studied. The imposed electric field was found, diverging the pH of permeate and retentate. This in turn altered the solubility of the calcium salt and impacted the performance of electro microfiltration membrane. Using electric field as an enhanced cleaning-in-place (CIP) method in back flushing SSS membrane was also studied.
机译:直接用作电极的烧结不锈钢(SSS)微滤膜用于分离乳制品加工中发现的Alamin(钙盐和蛋白质颗粒)的实验。研究了在外电场作用下SSS膜的结垢和清洁。发现施加的电场使渗透液和截留液的pH值发散。这继而改变了钙盐的溶解度并影响了电微滤膜的性能。还研究了在反冲洗SSS膜中使用电场作为增强的就地清洗(CIP)方法。