Isometric behavior of the reconstructed medial patellofemoral ligament using two different femoral pulleys: A cadaveric study

机译:使用两个不同的股骨滑轮重建media股内侧韧带的等距行为:尸体研究

获取原文
           

摘要

Background: Several techniques have been described for reconstructing the medial patellofemoral ligament (MPFL). However, the anatomy of the medial patellar retinaculum and the isometry of both intact and reconstructed MPFL remain controversial. The purpose of this study was to investigate the isometric behavior of the reconstructed MPFL when two different pulleys are used for the reconstruction.Material/Methods: Eight anatomical knees were dissected and the medial patellar retinaculum and MPFL were studied. A pilot technique for the reconstruction of the MPFL using a semitendinosus autograft was developed. A “dynamic” femoral fixation was chosen which utilized two different pulleys: the medial intermuscular septum (MIS) at the adductor’s tendon insertion and the posterior third of the medial collateral ligament (MCL). The isometric behavior of the reconstructed MPFL and the stability of both pulleys were investigated.Results: The MPFL was a thickened, band-like condensation of the superficial MPR layer extending from the MFE to the medial border of the patella. The reconstructed MPFL demonstrated the most isometric behavior when the MCL was used as a pulley. The average difference in graft length during knee flexion from 0° to 90° when the MCL or MIS were used as a pulley was 1 mm and 4 mm, respectively. The MIS pulley was more stable but less isometric than the MCL pulley.Conclusions: “Dynamic” MPFL reconstruction with a semitendinosus tendon autograft can restore patellofemoral stability without excessive soft-tissue dissection or implantation of hardware at the medial epicondyle, which can lead to symptoms of its own.
机译:背景:已经描述了几种重建pa股内侧韧带(MPFL)的技术。然而,内侧pa骨视网膜的解剖结构以及完整和重建的MPFL的等距线仍存在争议。这项研究的目的是研究当使用两个不同的滑轮进行重建时重建的MPFL的等距行为。材料/方法:解剖八个解剖膝盖,研究the骨内侧视网膜和MPFL。开发了一种使用半腱肌自体移植重建MPFL的试验技术。选择了一种“动态的”股骨固定术,它利用了两个不同的滑轮:内收肌腱插入处的内侧肌间隔膜(MIS)和内侧副韧带(MCL)的后三分之一。结果:MPFL是从MFE延伸到the骨内侧边界的MPR表层的增厚的带状凝结,研究了重建的MPFL的等距行为和两个滑轮的稳定性。当将MCL用作滑轮时,重建的MPFL表现出最大的等距行为。当将MCL或MIS用作滑轮时,膝关节屈曲时从0°到90°的移植长度平均差分别为1 mm和4 mm。 MIS滑轮比MCL滑轮更稳定,但等轴测不到。结论:半腱肌腱自体移植“动态” MPFL重建可恢复pa股稳定,而无需过度软组织解剖或在内侧上con上植入硬件,这可导致症状它自己的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号