首页> 外文期刊>Frontiers in Veterinary Science >Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
【24h】

Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses

机译:心电图仪和心率仪之间的一致性低,无法测量年轻耐力马运动时的心率变异性

获取原文
           

摘要

Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland-Altman analysis and the Lin’s coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, RMSSD, SD1, SD2, LF, HF) the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.
机译:对心率变异性(HRV)的分析在评估马业的训练实践和福利方面越来越重要。它依靠对连续心跳间隔中可靠而准确地测量到的变化(以RR间隔测量)进行数学分析。如今,RR间隔可以通过两种不同的技术获得:心率仪(HRM)或心电图(ECG)。这些设备的一致性和可靠性尚未得到充分评估,尤其是在运动过程中进行记录时。这项研究的目的是评估在标准化运动测试期间使用上述两种技术(HRM与ECG)进行HRV分析的两种商用器械的一致性。这两种装置在轻度运动和慢跑期间同时获得了36匹马的录音。使用Bland-Altman分析和Lin系数比较数据。从心电图和HRM获得的数据评估的HRV测量值之间的一致性仅在平均RR间隔和平均心率上是可以接受的。对于其他已研究的措施(SDNN,RMSSD,SD1,SD2,LF,HF),设备之间的协议太差了,以至于在这些记录条件下不能被认为是可互换的。当运动速度增加时,一致性也趋于恶化。因此,在解释和比较运动过程中HRV分析的结果时必须小心,因为结果将取决于记录设备。此外,设备软件中包含的更正和数据处理在很大程度上影响了后续HRV分析中使用的输出。在选择设备时必须考虑这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号