首页> 外文期刊>Materiales de Construccion >AFM study of steel corrosion in aqueous solutions in concrete
【24h】

AFM study of steel corrosion in aqueous solutions in concrete

机译:AFM研究混凝土水溶液中的钢腐蚀

获取原文
           

摘要

Early corrosion stages are studied in carbon steel by means of a solution simulating that contained in concrete pores. Non-carbonated solution contains 5% NaCl. The atomic force microscopy (AFM) technique is used to study material performance after different immersion times (up to 48 h). Obtained data are compared to electrochemical ones (corrosion potential and polarization resistance). Analysis of images and roughness evolution along time shows that steel initially tends to reach passivity, although the passive layer rapidly loses its protective character due to chloride attack.
机译:通过模拟混凝土孔隙中包含的溶液,研究了碳钢中的早期腐蚀阶段。非碳酸溶液包含5%NaCl。原子力显微镜(AFM)技术用于研究不同浸入时间(最长48小时)后的材料性能。将获得的数据与电化学数据(腐蚀电势和极化电阻)进行比较。分析图像和随时间变化的粗糙度表明,尽管钝化层由于氯化物的侵蚀而迅速失去了保护性,但钢最初趋于达到钝化。