This paper presents the results of laboratory tensile testing of segmentally-installed glue-in roof bolting. We studied roof bolting of the type Olkusz-16A (Boltech Sp. z o.o., ZGH Boles?aw S.A., Bukowno, Poland), additionally equipped with a steel rod coil, which was mounted in steel cylinders filled with a concrete mixture using multi-part resin cartridges with a diameter of 0.024 m and length of 0.045 m. The mounting depths were 0.1 m and 0.2 m, respectively. Our main purpose was to determine the effect of the bolt hole diameter, which assumed the values 0.028 m, 0.032 m, 0.035 m, and 0.037 m, respectively, on the load-bearing capacity of the roof bolting in relation to the mounting depth. We found that the mounting depth of 0.2 m was sufficient for the roof bolting to exhibit its full load and displacement properties for all four diameters of the bolt hole. To determine whether the roof bolting was capable of transferring the load in situ, we presented the results of the predicted load on the roof bolting applied in a room and pillar mining method in an underground mine of zinc and lead ore deposits. Our objective was to determine the influence of the room and pillar mining method geometry on the range of the fault zone of rocks around pits. We designed the deposit excavation model using the Examine3D numerical modeling software, which is based on the boundary element method. We created three-dimensional models for three variants of working space opening widths: featuring two, three, and four rows of rooms. The geometry of rooms and pillars corresponded to the mine conditions; the width, height, and length parameters were all 5 m. We determined the strength, strain, and structural parameters of the rock mass on the basis of laboratory studies of the drill core and rock forms collected from the room longwall. We used the strength factor to specify the maximum range of the fault zone of rocks around pits. In the last stage of research, we compared the load value obtained based on numerical testing with the maximum load obtained in the tensile strength tests of the roof bolting and determined the safety factor of the segmentally-installed roof bolting.
机译:本文介绍了分段安装的胶合屋顶锚固的实验室拉伸测试结果。我们研究了Olkusz-16A型(Boltech Sp。z oo,ZGH Boles?aw SA,波兰Bukowno,波兰)的屋顶锚杆,该锚杆还配有钢卷,该钢卷安装在装有多种混凝土混合物的钢瓶中,直径为0.024 m,长度为0.045 m的零件树脂滤芯。安装深度分别为0.1 m和0.2 m。我们的主要目的是确定螺栓孔直径对屋顶螺栓的承载能力(相对于安装深度)的影响,螺栓直径分别取值为0.028 m,0.032 m,0.035 m和0.037 m。我们发现,0.2 m的安装深度足以使屋顶螺栓在螺栓孔的所有四个直径上都能显示其满负荷和位移特性。为了确定屋顶锚杆是否能够原位传递载荷,我们介绍了在锌和铅矿石矿床的地下矿井中通过机房和柱子开采方法应用的屋顶锚杆的预测载荷结果。我们的目标是确定房间和立柱开采方法的几何形状对矿井周围岩石断层带范围的影响。我们使用Examine3D数值建模软件(基于边界元方法)设计了矿床开挖模型。我们为三种不同的工作空间开口宽度创建了三维模型:设有两排,三排和四排房间。房间和支柱的几何形状与矿山条件相对应。宽度,高度和长度参数均为5 m。我们根据实验室岩心和从房间长壁收集的岩石形态的实验室研究结果确定了岩体的强度,应变和结构参数。我们使用强度因子来指定坑周围岩石断层带的最大范围。在研究的最后阶段,我们将基于数值测试获得的载荷值与屋顶螺栓的拉伸强度测试中获得的最大载荷进行了比较,并确定了分段安装的屋顶螺栓的安全系数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号