摘要

The universal goniometer (UG) is the most frequently used tool for measuring range of motion (ROM), with demonstrated reliability. Computerized photogrammetry (CP) is widely used for postural assessment, but its role in the measurement of ROM of hip flexion and abduction has not yet been fully explored. This study aimed to test inter- and intra-rater reliability for measuring ROM of hip flexion and abduction using UG and CP, as well as the reliability between the instruments. Our sample consisted of 40 healthy volunteers (aged from 18 to 28 years). Measurements of ROM were conducted by two independent raters, 15 minutes apart, using UG and CP to assess inter-rater reliability. The procedures were repeated one week later by the first rater (intra-rater reliability). Using UG, inter-rater reliability was excellent for flexion and abduction (ICC=0.92 and 0.91, respectively); using CP, it was rated as very good (ICC=0.77 and 0.80, respectively). Intra-rater reliability using UG was excellent for flexion and abduction (ICC=0.95 and 0.92), and very good using CP (ICC= 0.81 and 0.89). The correlation between the instruments was excellent for flexion and very good for abduction (r=0.92 and r=0.82). Future investigations should seek a more diversified sample and symptomatic patients. Inter- and intra-rater reliability is high when measuring range of motion of hip flexion and abduction using both UG and CP, and the correlation between instruments is excellent for flexion and very good for abduction, meaning that both are valid.
机译:通用型测角仪(UG)是最常用的用于测量运动范围(ROM)的工具,具有公认的可靠性。计算机摄影测量法(CP)被广泛用于姿势评估,但是其在髋关节屈曲和外展ROM的测量中的作用尚未得到充分探索。这项研究旨在测试评定者之间和评定者内部的可靠性,以使用UG和CP测量髋关节屈曲和外展的ROM,以及仪器之间的可靠性。我们的样本包括40名健康志愿者(年龄在18至28岁之间)。 ROM的测量由两个独立的评估者进行,相隔15分钟,使用UG和CP评估评估者之间的可靠性。一周后由第一评价者重复该程序(评价者内部可靠性)。使用UG,评估者之间的屈曲和外展可靠性极佳(ICC分别为0.92和0.91)。使用CP时,它被评为非常好(ICC分别为0.77和0.80)。使用UG评估者的信度在屈曲和外展方面非常出色(ICC = 0.95和0.92),而使用CP则非常好(ICC = 0.81和0.89)。器械之间的相关性对于屈曲非常好,对于外展非常好(r = 0.92和r = 0.82)。未来的研究应寻找更多样化的样本和有症状的患者。当同时使用UG和CP测量髋部屈曲和外展的运动范围时,评定者之间和内部的可靠性很高,并且器械之间的相关性对于屈曲非常好,对于外展非常好,这意味着两者都是有效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号