Cervical pedicle screws have been reported to be biomechanically superior to lateral mass screws. However, placement of these implants is a technical challenge. The purpose of this investigation was to use an anatomic and a clinical study to evaluate a technique for placement of the pedicle screws in the C7 vertebra using fluoroscopic imaging in only the anteroposterior (A/P) plane. Ten adult cadaver C7 vertebrae were used to record the pedicle width, inclination and a suitable entry point for placement of pedicle screws. A prospective study of 28 patients undergoing posterior instrumentation of the cervical spine with C7 pedicle screw placement was also performed. A total of 55 C7 pedicle screws were placed using imaging only in the A/P plane with screw trajectory values obtained by the anatomic study. Radiographs and CT scans were performed post-operatively. The average posterior pedicle diameter of C7 vertebra was 9.5 ± 1.2 mm in this study. The average middle pedicle diameter was 7.1 mm and the average anterior pedicle diameter was 9.2 mm. The average transverse pedicle angle was 26.8 on the right and 27.3 on the left. CT scans were obtained on 20 of 28 patients which showed two asymptomatic cortical wall perforations. One screw penetrated the lateral wall of the pedicle and another displayed an anterior vertebral penetration. There were no medial wall perforations. The preliminary results suggest that this technique is safe and suitable for pedicle screw placement in the C7 vertebra.
机译:据报道颈椎椎弓根螺钉在生物力学上优于侧块螺钉。但是,这些植入物的放置是一项技术挑战。这项研究的目的是使用解剖学和临床研究来评估仅在前后(A / P)平面中使用荧光镜成像技术将椎弓根螺钉放置在C7椎骨中的技术。用十只成年尸体C7椎骨记录椎弓根的宽度,倾斜度和放置椎弓根螺钉的合适入口。还对28例接受颈椎后路C7椎弓根螺钉置入术的患者进行了前瞻性研究。仅通过成像将总共55个C7椎弓根螺钉放置在A / P平面中,并具有通过解剖学研究获得的螺钉轨迹值。术后进行X光片和CT扫描。在这项研究中,C7椎骨的平均后椎弓根直径为9.5±1.2 mm。椎弓根的平均中段直径为7.1mm,前椎弓根的平均直径为9.2mm。平均横向椎弓根角度在右侧为26.8,在左侧为27.3。对28例患者中的20例进行了CT扫描,显示出两个无症状的皮质壁穿孔。一个螺钉刺入椎弓根的侧壁,另一个螺钉刺入前椎骨。没有内侧壁穿孔。初步结果表明,该技术是安全的,适合于在C7椎骨中放置椎弓根螺钉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号