A comparative study using two different thiocyanate electrode designs was conducted; a solid type electrode (type A) and conventional liquid inner contact called electrode (type B). The fabrication of these electrodes was based on Al (III) [4-(2-Pyridylazo) resorcinol] (Al/PAR) and Mg (II) phthalocyanine (MgPC) complexes as a charged carrier,aliquate 336S and TDMAC as ion exchangers in plasticized poly (vinyl chloride) membrane. Electrodes type (A) revealed significantly enhanced response towards SCN - ions with displayed near-Nernstian slope of -53.7-55.8 mV decade -1 over the concentration range 5.0x10 -6 -1.0x10 -2 mol L -1 and a detection limit of 0.4-3.7 μg mL -1 . Type (B) sensors revealed near-Nernstian potential response to SCN - with a slope of -45.9-62.4 mV decade -1 over a linear range of 5.0x10 -5 - 1.0x10 -2 mol L -1 and a detection limit of 0.12-0.3 μg mL -1 . Membrane sensors based on (Al/PAR) and (MgPC) using the so called "fixed interference method" (FIM) exhibited a good selectivity over different anions which differ significantly from the classical Hofmeister series. All sensors were integrated in a flow system for continuous monitoring of thiocyanate under hydrodynamic mode of opration. The sensors revealed a frequency of ~ 54 samples h -1 . Application of the proposed sensors for SCN - determination in biological fluid samples such as saliva and urine collected from some non-smokers and smokers donors. Determination of cyanide content in electroplating wastewater samples after its conversion into thiocyanate was also applied. The results obtained from the proposed sensors were agreed with that obtained using the standard methods of thiocyanate and cyanide analysis.
机译:使用两种不同的硫氰酸盐电极设计进行了比较研究。固态电极(A型)和传统的液体内部触点称为电极(B型)。这些电极的制备基于Al(III)[4-(2-吡啶基偶氮)间苯二酚](Al / PAR)和Mg(II)酞菁(MgPC)络合物作为带电载体,铝酸盐336S和TDMAC作为离子交换剂。增塑的聚氯乙烯膜。电极类型(A)在5.0x10 -6 -1.0x10 -2 mol L -1的浓度范围内和检测极限为5,000 -1的情况下显示出对SCN离子的响应显着增强,显示的近能斯特斜率为-53.7-55.8 mV October -1。 0.4-3.7μg毫升-1。 (B)型传感器在5.0x10 -5-1.0x10 -2 mol L -1的线性范围内以及检测极限为0.12时显示出对SCN的近能斯特电位响应-斜率为-45.9-62.4 mV十进制-1 -0.3微克mL -1。基于(Al / PAR)和(MgPC)的膜传感器使用所谓的“固定干扰法”(FIM),对不同阴离子表现出良好的选择性,而这些阴离子与经典的Hofmeister系列显着不同。所有传感器均集成在流量系统中,可在流体动力学操作模式下连续监测硫氰酸盐。传感器显示〜54个样本h -1的频率。提议的传感器在SCN中的应用-测定从一些非吸烟者和吸烟者供体收集的唾液和尿液等生物液体样品中。还可以测定电镀废水中的氰化物含量,然后将其转化为硫氰酸盐。从建议的传感器获得的结果与使用硫氰酸盐和氰化物分析的标准方法获得的结果一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号