To design and assess indoor climate, thermal comfort, and the hygrothermal performance of a historic building it is essential to obtain data on the indoor temperature and humidity conditions. This paper analyses indoor climate conditions in historic wooden apartment buildings in Estonia and presents an applicable hygrothermal load model for designers. The average indoor temperature of 41 apartments in historic wooden apartment buildings was 21.0 ?°C in winter and 24.5 ?°C in summer. Using the indoor climate category III of the standard EN 15251, it was found that the temperature was outside the target values in 83% of the apartments in winter and in 25% in summer. Throughout the year, the indoor temperature was below the target values during 20% of the time while in winter it was above the target values during 4% of the time. Variations in indoor temperature reflect occupantsa€? main complaints about unstable temperature and cold floors during the winter period. The daily average moisture excess was 3.3 g/m3 during the cold period and 0.6 g/m3 during the warm period at the average air change rate of 0.56 ha€“1 and 0.79 ha€“1, respectively. Moisture generation indoors was 60 g/h at the average living density of 26 m2/person in the historic wooden apartment buildings. For stochastic analyses in historic wooden buildings, we developed an indoor hygrothermal load model that is in good agreement with measured results.
机译:要设计和评估历史建筑的室内气候,热舒适性和湿热性能,必须获取有关室内温度和湿度条件的数据。本文分析了爱沙尼亚历史悠久的木制公寓楼的室内气候条件,并为设计师提供了适用的湿热负荷模型。历史悠久的木制公寓楼中41套公寓的平均室内温度在冬季为21.0°C,在夏季为24.5°C。使用标准EN 15251的III类室内气候条件,发现冬季83%的公寓和夏季25%的公寓的温度均超出目标值。全年中,室内温度在20%的时间内低于目标值,而冬季则在4%的时间内高于目标值。室内温度的变化反映了居住者的状况。关于冬季不稳定的温度和寒冷的地面的主要​​抱怨。每天平均过量水分在寒冷时期为3.3 g / m3,在温暖时期为0.6 g / m3,平均空气变化率分别为0.56 ha-1和0.79 ha-1。在历史悠久的木制公寓中,室内的湿气产生量为60 g / h,平均生活密度为26平方米/人。为了对历史悠久的木制建筑进行随机分析,我们开发了一种室内湿热负荷模型,该模型与测量结果非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号