Errors in the Total Testing Process in the Clinical Chemistry Laboratory at the University of Gondar Hospital, Northwest Ethiopia

机译:埃塞俄比亚西北部贡达大学医院临床化学实验室的整体测试过程中的错误

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background Laboratory services have been described as the major processes contributing to safe patient care in the modern healthcare sector. However, occurrences of errors in the overall testing processes impair the clinical decision-making process. Such errors are supposed to be high in resource-poor countries, like Ethiopia. The objective of this study was to assess errors in the total testing process in the Clinical Chemistry laboratory of the University of Gondar Hospital, Northwest Ethiopia Methods A cross-sectional study was conducted at the University of Gondar Hospital from February to March 2016. All the required data were collected using established quality indicators. Data were analyzed using SPSS version 20. Frequencies and cross-tabulations were used to summarize descriptive statistics. Results A total of 3259 samples and corresponding laboratory request forms were received for analysis. The analysis of the overall distribution of errors revealed that 89.6% were pre-analytical errors, 2.6% were analytical, and 7.7% were post-analytical errors. Of the pre-analytical errors, incomplete request form filling was the most frequent error observed, followed by sample rejection rate (3.8%). Analytical errors related to internal and external quality control exceeding the target range, (14.4%) and (51.4%) respectively, were reported. Excessive turnaround time and unreported critical value cases were the major defects in the post-analytical phase of quality assurance. Conclusion The present finding showed relatively high frequency of errors, which alarms the importance of quality indicators to assess errors in the total testing process. The University of Gondar Hospital laboratory should improve the quality of healthcare services based on these findings using laboratory standards.
机译:背景技术实验室服务已被描述为现代医疗保健领域中促进患者安全护理的主要过程。但是,整体测试过程中出现错误会损害临床决策过程。在像埃塞俄比亚这样的资源匮乏的国家,这种错误率很高。这项研究的目的是评估在埃塞俄比亚西北部贡达大学医院临床化学实验室进行的总测试过程中的错误。方法横断面研究于2016年2月至2016年3月在贡达大学医院进行。使用已建立的质量指标收集所需的数据。使用SPSS 20版对数据进行分析。频率和交叉表用于总结描述性统计数据。结果共收到3259份样品和相应的实验室申请表进行分析。对错误总体分布的分析表明,分析之前的错误为89.6%,分析上的错误为2.6%,分析后的错误为7.7%。在分析前的错误中,填写不完整的申请表是最常见的错误,其次是样品拒绝率(3.8%)。报告了与内部和外部质量控制相关的分析误差,超出目标范围的分别为(14.4%)和(51.4%)。周转时间过长和临界值案例未报告是质量保证分析后阶段的主要缺陷。结论目前的发现显示出相对较高的错误发生率,这警告了质量指标在整个测试过程中评估错误的重要性。冈达大学医院的实验室应根据这些发现,使用实验室标准提高医疗服务的质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号