HDD production needs to be done in a clean room that keeps particulate contamination to the minimum. In planning a renovation of a clean room in an HDD factory in Thailand, a question came up whether to put components of HDD production machinery on raised platforms or keep them on the floor level in order to better minimize contamination. This study was conducted to find the answer using computational fluid dynamics (CFD) simulation software, Ansys Fluent, combined with the real ventilation conditions planned for the clean zone. The simulated results showed that keeping the machinery in the same level with the floor is more effective.
机译:HDD的生产需要在洁净室中进行,以将微粒污染降至最低。在计划对泰国HDD工厂中的洁净室进行翻修时,出现了一个问题,是将HDD生产机械的组件放置在高架平台上还是将它们放置在地板上,以更好地减少污染。这项研究是使用计算流体力学(CFD)模拟软件Ansys Fluent结合计划用于清洁区的实际通风条件来找到答案的。仿真结果表明,使机械与地板保持同一水平更为有效。