Abstract:Severe acute respiratory syndrome, or SARS, swept over the world in 2003, with 8,096 probable cases and 774 fatalities in 26 countries. Not immune to the outbreak, Taiwan accounted for 346 probable cases and 37 deaths. Exhaust air in negative isolation wards of SARS hospital is discharged through air shafts, extending directly to the roof; the shaft passes through the filter box and connects with a 5m chimney air shaft, where the exhaust is discharged into the atmosphere. The exhaust air has been tested to prove as safe to the public before exiting to the free air. However, to lower the sense of fear in the public, a dispersion model is requested by the Centers of Disease Control in Taiwan. The dispersion model can be an important reference if the filter system does not work properly. A CFD code is applied to calculate the non-dimensional concentration exhausting air from negative isolation wards. The predicting value of both the maximum concentration and the mean concentration is smaller than 0....
机译:摘要:2003年,严重急性呼吸综合征(SARS)风靡全球,在26个国家/地区发生8096例可能的病例,造成774人死亡。台湾无法幸免,有346例可能死亡,37例死亡。 SARS医院负隔离病房的废气通过气井排出,并直接延伸到屋顶。轴穿过过滤器箱并与5m烟囱空气轴相连,在此将废气排放到大气中。经测试,废气在释放到自由空气之前对公众安全。但是,为了降低公众的恐惧感,台湾疾病控制中心要求使用分散模型。如果过滤器系统无法正常工作,则色散模型可能是重要的参考。应用CFD代码计算负隔离病房排出的无量纲浓度的空气。最大浓度和平均浓度的预测值均小于0...。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号