首页> 外文期刊>Energy Science & Engineering >University of Texas study underestimates national methane emissions at natural gas production sites due to instrument sensor failure
【24h】

University of Texas study underestimates national methane emissions at natural gas production sites due to instrument sensor failure

机译:得克萨斯大学的研究低估了由于仪器传感器故障而导致天然气生产现场的甲烷排放量

获取原文
           

摘要

AbstractThe University of Texas reported on a campaign to measure methane (CH4) emissions from United States natural gas (NG) production sites as part of an improved national inventory. Unfortunately, their study appears to have systematically underestimated emissions. They used the Bacharach Hi-Flow® Sampler (BHFS) which in previous studies has been shown to exhibit sensor failures leading to underreporting of NG emissions. The data reported by the University of Texas study suggest their measurements exhibit this sensor failure, as shown by the paucity of high-emitting observations when the wellhead gas composition was less than 91% CH4, where sensor failures are most likely; during follow-up testing, the BHFS used in that study indeed exhibited sensor failure consistent with under-reporting of these high emitters. Tracer ratio measurements made by the University of Texas at a subset of sites with low CH4 content further indicate that the BHFS measurements at these sites were too low by factors of three to five. Over 98% of the CH4 inventory calculated from their own data and 41% of their compiled national inventory may be affected by this measurement failure. Their data also indicate that this sensor failure could occur at NG compositions as high as 97% CH4, possibly affecting other BHFS measurement programs throughout the entire NG supply chain, including at transmission sites where the BHFS is used to report greenhouse gas emissions to the United States Environmental Protection Agency Greenhouse Gas Reporting Program (USEPA GHGRP, U.S. 40 CFR Part 98, Subpart W). The presence of such an obvious problem in this high profile, landmark study highlights the need for increased quality assurance in all greenhouse gas measurement programs.
机译:摘要德克萨斯大学报告了一项运动,该运动旨在测量美国天然气(NG)生产现场的甲烷(CH 4 )排放,以此作为改进的国家清单的一部分。不幸的是,他们的研究似乎系统地低估了排放量。他们使用了Bacharach Hi-Flow ®采样器(BHFS),在先前的研究中,该采样器已显示出传感器故障,导致NG排放报告不足。德克萨斯大学研究报告的数据表明,他们的测量结果显示出这种传感器故障,如井口气体成分小于91%CH 4 时高发射观测的缺乏所表明的,其中传感器故障最有可能在后续测试中,该研究中使用的BHFS确实表现出传感器故障,与这些高辐射源的报告不足相一致。德克萨斯大学在CH 4 含量低的部分站点进行的示踪剂比测量进一步表明,这些站点的BHFS测量值太低了三到五倍。根据他们自己的数据计算出的CH 4 清单中超过98%的数据和他们编制的国家清单中41%的数据可能会受到此测量失败的影响。他们的数据还表明,这种传感器故障可能发生在天然气成分高达97%CH 4 的情况下,可能影响整个天然气供应链中的其他BHFS测量程序,包括使用BHFS的传输地点。向美国环境保护署温室气体报告计划(USEPA GHGRP,美国40 CFR第98部分,W子部分)报告温室气体排放。在这一备受瞩目的具有里程碑意义的研究中,存在如此明显的问题,突显了在所有温室气体测量计划中都需要提高质量保证的必要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号