首页> 外文期刊>International Journal of Dentistry >Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material
【24h】

Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material

机译:用Er,Cr:YSGG激光在有无根端填充材料的情况下对根端切除进行评估

获取原文
           

摘要

Microleakage following root-end resections has a direct influence on the outcome of surgical endodontic procedures. This study compared the microleakage after root-end resections performed by the Er, Cr: YSGG laser or carbide burs with or without the placement of MTA, and evaluated the presence of microcracks and gaps at the interface of GP/MTA and the canal walls. Ninety single-rooted teeth were instrumented, obturated with GP and AH-Plus sealer, and divided into 3 experimental groups: (I) root-end resections were performed with the laser and G6 tips (parameters: 4.5 w, 30 pps, 20% water and 50% air); (II) Lindeman burs were used, without the placement of MTA; (III) the burs were used followed by root-end fillings with MTA, and one control (IV) of five unobturated roots resected with the burs. The samples were prepared for microleakage (n=20) and SEM (n=10) analysis. They were immersed in 1% methylene blue, decalcified, cleared, and evaluated for dye penetration (mm2) with the ImageJ software. Epoxy-resin replicas of the root-ends were analyzed by SEM for gaps (μm2) and microcracks. Microleakage results were0.518±1.059,0.172±0.223, and0.158±0.253, for the laser (I), no root-end filling (II), and MTA (III) samples, respectively, (ANOVAP=.02). The laser (7831.7±2329.2) and no root-end filling (7137.3±1400.7) samples presented gaps. Whereas, none was found in the MTA (ANOVAP=.002). Microcracks were not observed. The MTA group demonstrated statistically less leakage and better adaptation to the canal walls when compared to the other groups. There was no correlation between the size of the gaps and the degree of microleakage.
机译:根端切除术后的微渗漏对外科牙髓手术结果有直接影响。这项研究比较了在有或没有放置MTA的情况下,用Er,Cr:YSGG激光或硬质合金钻头进行根端切除后的微渗漏,并评估了GP / MTA与管壁界面处微裂纹和间隙的存在。植入90根单根牙齿,用GP和AH-Plus封闭器封闭,并分成3个实验组:(I)用激光和G6尖端进行根端切除术(参数:4.5 w,30 pps,20%水和50%的空气); (II)使用林德曼针,不放置MTA; (III)使用burs,然后用MTA填充根端,并用burs切除5个未阻塞根的对照(IV)。准备样品进行微渗漏(n = 20)和SEM(n = 10)分析。将它们浸入1%的亚甲基蓝中,脱钙,清除,并使用ImageJ软件评估染料的渗透率(mm2)。通过SEM分析根端的环氧树脂复制品的间隙(μm2)和微裂纹。对于激光(I),无根端填充物(II)和MTA(III)样品,微渗漏结果分别为0.518±1.059、0.172±0.223和0.158±0.253(ANOVAP = .02)。激光(7831.7±2329.2)和无根端填充(7137.3±1400.7)的样品均出现间隙。而在MTA中没有发现(ANOVAP = .002)。没有观察到微裂纹。与其他组相比,MTA组在统计学上显示出较少的渗漏,并且更好地适应了管壁。间隙的大小和微渗漏程度之间没有相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号