References(11) Cited-By(2) For predicting the response of a fire detector in an actual fire, it is important to evaluate the transient properties of the ceiling jet, to which the fire detector is exposed. In this study, a relatively simple and yet accurate enough calculation method was developed by combining a two-layer zone model and an unconfined ceiling jet model to predict the optical smoke density in a ceiling jet.The method mutually compensates the weakness of the two-layer zone model, which can only predict the average temperature of the interior upper layer, and the weakness of the ceiling jet model, which is not suited for a closed space surrounded by walls. The prediction formula is validated by the fire experiments conducted using the test fire procedure as prescribed in an ISO/TC21/SC3's standard (draft) for fire detection and fire alarm systems.
机译:参考文献(11)Cited-By(2)为了预测实际火灾中火灾探测器的响应,重要的是评估火灾探测器所暴露的天花板射流的瞬态特性。在这项研究中,通过结合两层区域模型和无限制天花板射流模型来预测天花板射流中的光学烟气密度,开发了一种相对简单但足够准确的计算方法,该方法相互弥补了两层模型的缺点:层区域模型,它只能预测内部上层的平均温度,而顶棚射流模型的缺点是,它不适用于墙壁环绕的封闭空间。预测公式通过使用符合ISO / TC21 / SC3标准(草案)的火灾探测和火灾报警系统中规定的试验着火程序进行的着火实验进行验证。