Reproducibility of Retinal Nerve Fiber Layer Measurements with Manual and Automated Centration in Healthy Subjects Using Spectralis Spectral-Domain Optical Coherence Tomography

机译:使用Spectralis光谱域光学相干层析成像技术在健康受试者中手动和自动定心视网膜神经纤维层测量的可重复性

获取原文
           

摘要

Objective. The aim of this study was to test the reproducibility of the Heidelberg Spectralis SD-OCT and to determine if provided software retest function for follow-up exam is superior to manual centration.Design. Prospective, cross-sectional study.Participants. 20 healthy subjects.Methods. All subjects underwent SD-OCT testing to determine retinal nerve fiber layer (RNFL) measurements sequentially on two different days and with two different centration techniques. Within-subject standard deviation, coefficient of variation, and intraclass correlation coefficient were used to assess reproducibility.Results. RNFL measurements showed high reproducibility, low within-subject standard deviation (1.3), low coefficient of variation (0.63%), and low intra-class correlation coefficient (0.98 (95% CI 0.97–0.99)) in the automated centration and manual centration groups for average RNFL Thickness. Quadrants showed slightly higher variability in the manual group compared to the automated group (within-subject standard deviation 2.5–5.3 versus 1.1–2.4, resp.).Conclusions. SD-OCT provides high-resolution RNFL measurements with high reproducibility and low variability. The re-test function allows for easier recentration for longitudinal examinations with similar results in average RNFL, but less variability in quadrant RNFL. SD-OCT high reproducibility and low variability is a promising fact and should be further evaluated in longitudinal studies of RNFL.
机译:目的。这项研究的目的是测试Heidelberg Spectralis SD-OCT的可重复性,并确定所提供的跟进检查软件重测功能是否优于手动定心设计。前瞻性,横断面研究。 20名健康受试者。方法。所有受试者均经过SD-OCT测试,分别在两天的不同日期和两种不同的定心技术下确定视网膜神经纤维层(RNFL)的测量值。受试者内标准差,变异系数和组内相关系数用于评估可重复性。 RNFL测量结果显示,在自动定心和手动定心中,重现性高,受试者内部标准差低(1.3),变异系数低(0.63%)和组内相关系数低(0.98(95%CI 0.97-0.99))平均RNFL厚度分组。与自动化组相比,手动组的象限显示出更高的变异性(受试者内部标准差分别为2.5–5.3和1.1–2.4,分别为。)。 SD-OCT提供具有高重现性和低变异性的高分辨率RNFL测量。重新测试功能使纵向检查更容易重新定位,平均RNFL的结果相似,但象限RNFL的变异性较小。 SD-OCT的高重现性和低变异性是一个有希望的事实,应在RNFL的纵向研究中进一步评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号