首页> 外文期刊>International Journal of Power Electronics and Drive Systems >Motor Command and Supervision Using the Magnetic Components of the Insulation Fault Protection System for Power Line Communication
【24h】

Motor Command and Supervision Using the Magnetic Components of the Insulation Fault Protection System for Power Line Communication

机译:电力线通信中使用绝缘故障保护系统的磁性元件进行电机指令和监控

获取原文
           

摘要

This work proposes an additional function for a VSD (Variable Speed Drive) which sends and receives information over the power lines and simultaneously, implements the protection against insulation faults to earth. Using the magnetic components of the insulation fault protection system of the motor, the prototype injects and detects the communication signals over the power line. The system works on both communication schemes, with and without the PWM (Pulse Width Modulation) perturbation in the power lines, which are the two possible real applications. In order to set a proper communication between the motor and the drive, the communication channel was modeled and the noise was characterized. An FSK modulation and demodulation scheme was developed and tested. A 10 kbps communication over a 125 m length of cable and over a 1 km pi-section model of the same cable was successfully achieved with the laboratory prototype.
机译:这项工作为VSD(变速驱动器)提出了一项附加功能,该功能通过电源线发送和接收信息,同时实现对接地绝缘故障的保护。原型使用电动机绝缘故障保护系统的磁性组件,通过电力线注入并检测通信信号。该系统适用于两种通信方案,在电源线中有无PWM(脉冲宽度调制)干扰,这是两种可能的实际应用。为了在电动机和驱动器之间建立适当的通信,对通信通道进行了建模并确定了噪声。开发并测试了FSK调制和解调方案。实验室原型成功实现了125 m电缆长度和同一电缆的pi截面模型的10 kbps通信。