The recirculation of marinade used in commercial poultry injection applications can pose a microbiological concern if not handled properly. In an attempt to solve this problem, a spent sample (30 gallons) of a typical poultry marinade was collected after production from a USDA-inspected poultry facility and was shipped overnight to MCA Services (Rogers, AR) under refrigerated conditions. The solution was microbiologically evaluated for natural microflora and had an existing Aerobic Plate Count (using APC Petrifilm3) of 5.5 logs per mL (colony forming units). Three trials were conducted with the Fresh Light ? 210 ultraviolet light system (Safe Foods Corporation, N. Little Rock, AR) using three different flow rates and corresponding solution turnover times to determine the optimum flow rate (and turnover time) for microbial control. The three flow rates were 10, 20 and 30 gallons per minute with corresponding solution turnover times of approximately 3, 1.5 and 1 minutes. As solution turnover rate decreased (from 3 minutes to 1 minute), the time necessary to achieve a 1 log microbial reduction (90% reduction) decreased from 9 minutes at a turnover rate of 3 minutes to 7.5 minutes at a turnover rate of 2 minutes and to approximately 5 minutes at a turnover rate of 1 minute. Regardless of flow rate or solution turnover time, the total bacterial count in the marinade solution was effectively reduced by approximately 1 log in less than 10 minutes of operational time with the Fresh Light ? 210 ultraviolet light system. These trials clearly demonstrate that the commercially available Fresh Light ? 210 ultraviolet light system (FDA regulated under 21 CFR 179.39) can provide the manufacturer with an effective means of controlling the microbial load in poultry marinade solutions at a very low cost. The data also suggest that as solution turnover rate decreases the time necessary to effectively reduce bacterial levels decreases but that this difference is not substantial in regards to actual time in minutes between normal operational flow rates of 10 to 30 gallons per minute.
机译:如果处理不当,用于商业家禽注射应用的腌泡汁再循环可能会引起微生物问题。为了解决此问题,生产后从美国农业部检验的家禽设施中收集了一份典型的家禽腌料的废样品(30加仑),并在冷藏条件下过夜运往MCA Services(罗杰斯,AR)。对该溶液进行了自然微生物区系的微生物学评估,现有的需氧菌数(使用APC Petrifilm3)为5.5 log / mL(菌落形成单位)。使用Fresh Light?进行了三个试验。 210紫外灯系统(美国北卡罗来纳州N. Little Rock的安全食品公司)使用三种不同的流速和相应的溶液周转时间来确定用于微生物控制的最佳流速(和周转时间)。三种流速分别为每分钟10加仑,20加仑和30加仑,相应的溶液周转时间约为3分钟,1.5分钟和1分钟。随着溶液周转率的降低(从3分钟减少到1分钟),实现1 log微生物减少(减少90%)所需的时间从周转率3分钟的9分钟减少到周转率2分钟的7.5分钟。并以1分钟的周转率减少到大约5分钟。不管流速或溶液周转时间如何,使用Fresh Light?在不到10分钟的操作时间内,腌汁溶液中的细菌总数均有效减少了约1 log。 210紫外线系统。这些试验清楚地表明,市售的Fresh Light? 210紫外线系统(FDA根据21 CFR 179.39监管)可以为制造商提供有效的方法,以非常低的成本控制家禽腌泡液中的微生物负荷。数据还表明,随着溶液周转率的降低,有效降低细菌水平所需的时间也将减少,但就正常运行时间(每分钟10至30加仑)之间的分钟实际时间而言,这种差异并不重大。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号