首页> 外文期刊>International Journal of Nuclear Energy >Experimental Measurements of Drop Size Distributions in 30 mm Diameter Annular Centrifugal Contactor with 30% TBP-Nitric Acid Biphasic System
【24h】

Experimental Measurements of Drop Size Distributions in 30 mm Diameter Annular Centrifugal Contactor with 30% TBP-Nitric Acid Biphasic System

机译:30%TBP-硝酸双相系统在直径30 mm的环形离心接触器中液滴尺寸分布的实验测量

获取原文
           

摘要

For design and development of liquid-liquid extraction systems, it is essential to have an accurate estimation of hydrodynamic and mass transfer characteristics of the employed contactor. In the present study, experimental evaluations consisted primarily of determining the maximum solution throughput that could be processed without cross-phase contamination at a given rotor speed, O/A flow ratio, and organic-aqueous solution pair in a 30 mm bowl diameter centrifugal contactor. In addition, analysis included experimental drop size determinations as well as holdup determination. The experimental drop size distributions are expected to be helpful for modeling work.
机译:对于液-液萃取系统的设计和开发,必须准确估算所用接触器的流体动力学和传质特性。在本研究中,实验评估主要包括确定在给定的转子速度,O / A流量比和30μmm碗径离心接触器中的有机水溶液对的情况下,在没有交叉相污染的情况下可以处理的最大溶液通量。 。此外,分析还包括实验滴大小的确定以及滞留率的确定。实验性的墨滴尺寸分布有望对建模工作有所帮助。