首页> 外文期刊>International journal of low carbon technologies >Experimental study of a thermoelectric heat pump system utilizing bent heat pipes for heat transfer
【24h】

Experimental study of a thermoelectric heat pump system utilizing bent heat pipes for heat transfer

机译:利用弯曲热管进行热传递的热电热泵系统的实验研究

获取原文
           

摘要

This paper presents the study of the novel thermoelectric heat pipe heat pumping system. Bent heat pipes with sintered powder wicks were utilized in a configuration which used centrifugal forces, due to rotation, to enhance heat transfer. The revolving heat pipes worked both as a fan and as a heat exchanger; however, extra fan blades were required to improve the fan performance. Fan performance tests were carried out, followed by the thermal performance, within which eight pieces of thermoelectric devices were applied to provide the heat pumping. The results showed that the system could provide airflows of up to 168.7 m3/h with the revolving speed of 600 RPM, and maximum static pressure was up to 37 Pa. The system could supply the heating of up to 257.1 W with the coefficient of performance of up to 1.96. Comparisons were made between the revolving and stationary systems, and the results showed that the former increased the thermal performance by up to 10% in heating and up to 20% in cooling.
机译:本文介绍了新型热电热管热泵系统的研究。具有烧结粉末芯的弯曲热管以这样的构造使用,该构造利用由于旋转而产生的离心力来增强热传递。旋转的热管既充当风扇又充当热交换器。但是,需要额外的风扇叶片以提高风扇性能。进行了风扇性能测试,然后进行了热性能测试,在其中应用了八块热电装置来提供热泵。结果表明,该系统以600 RPM的转速提供高达168.7 m 3 / h的气流,最大静压高达37 Pa。至257.1 W,性能系数高达1.96。对旋转系统和固定系统进行了比较,结果表明,前者将加热时的热性能提高了10%,将冷却时的热性能提高了20%。