摘要

Distribution network equipment failure causes a serious impact on society. So a reasonable approach to reduce the consequences of equipment failure (ie, equipment failure affecting degrees) is necessary. This paper presents a comprehensive evaluation method which combines fault traversal, AHP-TOPSIS method to ensure the degree of different equipment failures. Meanwhile, in order to reduce the impact of equipment failure, a distributed power is accessed into distribution network, and we compared the impact value before and after it accessed. A numerical example shows that the distributed power can reduce the consequences of equipment failure as well as the grid and social impacts.
机译:配电网络设备故障对社会造成严重影响。因此,需要一种合理的方法来减少设备故障的后果(即设备故障影响程度)。本文提出了一种综合故障评估的综合评估方法,即AHP-TOPSIS法,以确保不同设备的故障程度。同时,为了减少设备故障的影响,将分布式电源接入配电网,并比较了接入前后的影响值。数值示例表明,分布式电源可以减少设备故障以及对电网和社会的影响。