To analyze the reason for replacement, revision and overall satisfaction of a cohort who underwent surgical replacement of an inflatable penile prosthesis (IPP). A cohort of 105 patients who underwent IPP replacement from 2005–2007 was retrieved from the prosthesis database. Approximately 21.9% (23) underwent replacement or revision of their prosthesis because of complications, and were further analyzed. Reason for removal was stratified into infectious and non-infectious (erosion, non-function and patient discomfort). Age, race (African American vs non-African American), smoking history, hypertension, diabetes, coronary artery disease and hyperlipidemia were stratified by reason for removal. Finally, we contacted patients and recorded subjective satisfaction with their IPP. The reason for removal was most commonly because of a non-functional IPP (47.8%), followed by infection (30.4%), erosion (17.4%) and patient discomfort (4.3%). Age and race did not show a significant difference when analyzing reason for replacement (P>0.05). Patients who were smokers (P=0.907) had hypertension (P=0.554), diabetes (P=0.591) or hyperlipidemia (P=0.219) did not have significantly higher infection rates. Approximately 58.3% were satisfied with their prosthesis, 75% would have the surgery performed again and 91.7% would still recommend prosthesis surgery. Device malfunction was the primary reason for replacement/removal at our institution. Despite the complications of prosthesis reoperation, the majority of patients were still satisfied with their prosthesis, would have the surgery performed again and would recommend prosthesis surgery to a friend.
机译:为了分析接受充气阴茎假体(IPP)手术置换的队列的替换,修订和总体满意度的原因。从假体数据库中检索了2005年至2007年间接受IPP置换的105例患者。约有21.9%(23)的患者因并发症而更换或翻修了其假体,并进行了进一步分析。去除的原因分为感染性和非感染性(侵蚀,无功能和患者不适)。年龄,种族(非裔美国人与非裔美国人),吸烟史,高血压,糖尿病,冠状动脉疾病和高脂血症按清除原因分层。最后,我们联系了患者并记录了他们对IPP的主观满意度。移除的原因最常见是由于IPP无法正常运行(47.8%),其次是感染(30.4%),糜烂(17.4%)和患者不适(4.3%)。在分析更换原因时,年龄和种族没有显着差异(P> 0.05)。吸烟者(P = 0.907)患有高血压(P = 0.554),糖尿病(P = 0.591)或高脂血症(P = 0.219)的感染率没有明显升高。大约58.3%的人对他们的假体感到满意,其中75%的人会再次进行手术,而91.7%的人仍然推荐假体手术。设备故障是我们机构更换/拆卸的主要原因。尽管假体再手术存在并发症,但大多数患者仍对假体感到满意,可以再次进行手术,并向朋友推荐假体手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号