...
首页> 外文期刊>International Journal of Exercise Science >Cardiovascular Responses Between Low Cadence/High Force vs. High Cadence/Low Force Cycling
【24h】

Cardiovascular Responses Between Low Cadence/High Force vs. High Cadence/Low Force Cycling

机译:低节奏/高强度循环与高节奏/低强度循环之间的心血管反应

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The purpose of this study was to determine the cardiovascular responses during sustained power output comparing low cadence (LC) high force (HF) vs. high cadence (HC) Low force (LF) cycle ergometry. Nine participants (N = 9) volunteered for this study. Participants signed a Human Participants consent form. A power output of 150 watts (W) for 20 minutes was estimated as the sustainable workload. Participants were instructed to pedal steadily at 50 rpm (LC) or 100 rpm (HC) with resistance adjusted to sustain 150 W. The following measures were obtained each minute during the 20-minute protocol: average heart rate (b*min.-1), blood pressure (mmHg) and Rate Pressure Product (i.e. RPP= (SBP * HR)*100-1). Randomization was used to counterbalance both protocols (HC vs. LC) and demographic controls (N=9). Means and standard deviations (SD) were determined for age (36 ± 13.64 years), resting heart rate (68.83 ± 11.95 b*min-1), resting blood pressure (126.42 ± 13.27 mmHg), body fat percentage (male: 14.7 ± 4.3 %; female 20.6 ± 1.3 %) and height (157.80 ± 10.04 cm). A Repeated Measures Analysis of Variance (RM-ANOVA) was utilized to compare exercising values between test protocols. A Pearson Product Correlation Coefficient was utilized to determine bivariate associations between variables. A Tukey Post Hoc analysis was performed to analyze differences in LC HR and RPP. Statistical significance was set a priori at p < 0.05. There were statistical differences among LC ±HR (130.51 ± 3.36), HC HR (150.83±6.49), LC RPP (204.63± 11.45), and HC RPP (245.57±25.70) Between the HC and LC protocols, the use of HC protocol elicited an increase in HR and RPP.
机译:这项研究的目的是通过比较低踏频(LC)高推力(HF)与高踏频(HC)低推力(LF)循环测功法确定持续功率输出期间的心血管反应。 9名参与者(N = 9)自愿参加了这项研究。参加者签署了人类参加者同意书。据估计,持续20分钟的输出功率为150瓦。指示参与者以50 rpm(LC)或100 rpm(HC)稳定地踩踏,并调整电阻以维持150W。在20分钟的实验方案中,每分钟获得以下测量值:平均心率(b * min.-1) ),血压(mmHg)和速率压力乘积(即RPP =(SBP * HR)* 100-1)。随机化用于抵消方案(HC vs. LC)和人口统计学对照(N = 9)。确定年龄(36±13.64岁),静息心率(68.83±11.95 b * min-1),静息血压(126.42±13.27 mmHg),体脂百分比(男性:14.7±)的平均值和标准差(SD) 4.3%;雌性20.6±1.3%)和身高(157.80±10.04 cm)。方差重复测量分析(RM-ANOVA)用于比较测试方案之间的锻炼值。皮尔逊积相关系数用于确定变量之间的双变量关联。进行了Tukey Post Hoc分析,以分析LC HR和RPP的差异。统计学显着性设定为p <0.05。在HC和LC方案之间,使用HC方案的LC±HR(130.51±3.36),HC HR(150.83±6.49),LC RPP(204.63±11.45)和HC RPP(245.57±25.70)之间存在统计差异导致HR和RPP增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号