首页> 外文期刊>International Journal of Engineering Science and Technology >COMPARISON OF DSTATCOM TOPOLOGIES FOR HARMONIC MITIGATION IN INDUCTION FURNACE
【24h】

COMPARISON OF DSTATCOM TOPOLOGIES FOR HARMONIC MITIGATION IN INDUCTION FURNACE

机译:感应炉谐波缓解的Dstatcom拓扑比较

获取原文

摘要

Harmonics associated with the operation of an induction furnace under varying load conditions result in huge power losses and have a negative affect on nearby loads. The aim of the present work is harmonic mitigation using a Distribution Static Compensator (DSTATCOM) to mitigate the harmonic content of a steel plant employing an induction furnace (IF). A Simulink model of the IF, whose performance matches the real time data obtained from a steel plant IF in operation, is designed. The performance with the application of three topologies, i.e. low level (7-level), intermediate level (11-level) and high level (15-level), of Cascaded Multilevel Inverter (CMLI) based DSTATCOM is evaluated and compared. The results show remarkable improvement in the voltage profile and Total Harmonic Distortion (THD) of the IF.
机译:在变化的负载条件下与感应炉运行相关的谐波会导致巨大的功率损耗,并对附近的负载产生负面影响。本工作的目的是使用配电静态补偿器(DSTATCOM)减轻谐波,以减轻采用感应炉(IF)的钢铁厂的谐波含量。设计了中频的Simulink模型,其性能与从钢铁厂中频运行中获得的实时数据相匹配。评估和比较了基于层叠拓扑多电平逆变器(CMLI)的三种拓扑(低级(7级),中级(11级)和高级(15级))的性能。结果表明,IF的电压曲线和总谐波失真(THD)显着改善。