Electrochemical Behavior of Reinforced Concrete and Its Relation With the Environment of Xalapa, Veracruz

机译:韦拉克鲁斯州Xalapa的钢筋混凝土的电化学行为及其与环境的关系

获取原文

摘要

In this work it is evaluated the electrochemical performance of reinforced concrete exposed to theenvironment of the city of Xalapa, Veracruz, to portray the effect in the durability, since this dependsnot only from its mechanical features but also from the environment in which the structure will bebuild, as it has been demonstrated in some researches. 12 beams of 15 x 15 x 30 cm were made, 6 withsteel to reinforce and 6 without it. Two types of concrete were designed, one with a w/c = 0.65 ratioand the other with a w/c = 0.45 ratio, with the same kind of cement, 3/8diameter 1018 steel carbonrods, in three types of coating thickness, 15, 20 and 30 mm. The tests to evaluate the oversensitivity tocorrosion of the reinforce steel, were resistance to polarization and the monitoring of potentialcorrosion based in the standard ASTM C-876-09.The obtained results of the first two years ofmonitoring indicate us noble potentials that indicate a 10% probability of corrosion, the kinetics ofcorrosion is negligible for 12 rods since 6 of them have a moderate level of corrosion.
机译:在这项工作中,我们评估了暴露于韦拉克鲁斯州Xalapa市环境中的钢筋混凝土的电化学性能,以说明耐久性的影响,因为这不仅取决于其机械特性,还取决于建造该结构的环境,正如一些研究已证明的那样。制作了12根15 x 15 x 30厘米的横梁,其中6根是用钢加固的,而6根是没有钢的。设计了两种类型的混凝土,一种以aw / c = 0.65的比率,另一种以aw / c = 0.45的比率,使用相同类型的水泥,3/8直径1018钢碳棒,三种涂层厚度分别为15、20和30毫米根据标准ASTM C-876-09评估钢筋对腐蚀的超敏性的测试是对极化的抵抗力和对潜在腐蚀的监测。头两年监测的结果表明,我们的贵金属潜力表明10%由于存在腐蚀的可能性,因此12根棒的腐蚀动力学可以忽略不计,因为其中6根棒的腐蚀程度中等。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号